Installation Guide

MorphoAccess® VP MD – Installation Guide
Section 3 :Installation Procedure
2019_200000XXXX-V0
IDEMIA DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED
December 2018
Step by step procedure
The recommended height for fixing of the terminal lies between 1m and 1.20m.
For an optimal use the terminal must be installed in an area where the
lighting conditions are controlled. Avoid direct exposure of the sensor to
the sun light.
Power supply from electrical source shall be switched off before starting
the installation.
The strength of the attachment depends on the solidity of the wall on
which the terminal is mounted.
The adhesive foam joint at the back of the wall plate is required for sealing
purposes (watertightness). If walls have a rough or uneven surface, a
silicon bead may be required between the wall plate and the wall to
ensure sealing.
Drilling the mounting holes
If not present, drill in the wall a hole with a diameter adapted to the width of the
terminal and the cable to be hosted in (see Figure 7: Drilling template This template at
scale 1:1 can be found in the Quick Installation Guide).
Confirm the presence inside the hole of all the cables needed for the electrical
installation (see Electrical Interface)
Drill in the wall 2 holes with a diameter adapted to screws and fit them with the raw
plugs (see Figure 7: Drilling template and Figure 8: Wall plate fixing).