Wiring overview
Before proceeding, make sure that the person in charge of installation and
connections is properly connected to earth, in order to prevent
Electrostatic Discharges (ESD).
Power supply ground shall not be used for peripheral ground. All other
grounds can be used indifferently.
Note that all connections of the MorphoAccess® VP MD terminal described hereafter
are of SELV (Safety Electrical Low Voltage) type.
Figure 11: Cabling layout
RJ45
USB
19 Green / Red WIEG_IN_D0
20 White / Red WIEG_IN_D1
21 Green WIEG_OUT_D0
23 White WIEG_OUT_D1
24 Blue WIEG_OUT_LED1
22 Blue / Red WIEG_OUT_LED2
18 Black / Red WIEGAND_GND
15 Blue / Black RS485_RX+/TX+ (A)
13 Blue / White RS485_RX-/TX- (B)
17 Black / Red RS485_GND
1 Red Power +12V
2 Black Power GND
3 Light Blue SWITCH_PIN1
4 Pink SWITCH_PIN2
5 Yellow / White RELAY_NO
6 Grey / White RELAY_COM
7 Orange / White RELAY_NC
9 Orange GPI0
11 Orange / Red GPI1
16 Orange / Black GPI2
10 Yellow GPO0
8 Yellow / Red GPO1
14 Yellow / Black GPO2
12 Black / Red GPIO_GND