Output Relay
Figure 13: Output relay wiring
5
Yellow / White
Relay NO
Contact relay (normally open)
6
Grey / White
Relay COM
Contact relay common
7
Orange / White
Relay NC
Contact relay (normally closed)
Nominal characteristics of relay
Load characteristics:
1 A max @ 30 VDC (according to the safety extra low voltage requirements
independently of the power supply),
Resistive load or inductive load; see warning information hereafter for inductive
load.
The internal relay is designed for at least 100 000 cycles.
Inductive load management requires a parallel diode for a better contact
lifetime.
Example of connection for electrical door locks
Figure 14: Example of electric door strike connection
+
VCC <30V
Imax < 1A
Electric
door lock
Protection
diode
MorphoAccess®
VP MD Terminal
Button on other
side of the door
Relay
Pin 1
Relay
Pin 2