1.3 > Safety Instructions
means Direct Current (DC)
The installation of this product should be made by a qualified service Person and should comply with all
local regulations.
It is strongly recommended to use a class II power supply at 12V-24V and 3 A min (at 12V) in conformity
with Safety Electrical Low Voltage (SELV). The power supply cable length should not exceed 10 meters.
This system must be installed in accordance with the National Electrical Code (NFPA 70), and the local
authority having jurisdiction.
This product is intended to be installed with a power supply complying with IEC60950-1, in accordance
with the NEC Class 2 requirements; or supplied by a listed IEC60950-1 external Power Unit marked Class
2, Limited Power source, or LPS and rated 12VDC, 3 A minimum or 24VDC, 1.5 A minimum.
Note that all connections of the VisionPass terminal described hereafter are of SELV (Safety Electrical
Low Voltage) type.