Installation Guide

31
VisionPass - 2019_2000045728
3.2 > Installation
Required tools (not supplied)
Four (4) raw plugs + four (4) screws ø4mm max and length adapted to the wall material.
One (1) screwdriver adapted to screws above.
One (1) Drill (with a drill bit diameter adapted to raw plugs above).
One (1) hole saw (depending on installation case).
A (1) CHC H2 screwdriver
A (1) CHC H2.5 screwdriver
Deadbolt/door strike
Snubber diode required to protect regulated DC power supply from inductive kickback (1N4007 diode
or equivalent recommended)
Separate power supply for the deadbolt/door strike based on supplier's recommendations.
External relay (if required)
Networking cable
For UL-294 compliance, an earthed screen in the wire or around all wires to/from product is only required
when the wires share space/compartment/tube with high voltage cables.
Equipment from the initial package to use
One (1) Terminal’s body.
One (1) wall plate.