Before cabling the product, remove the connector by cutting cables in the middle of heat shrink tube.
Please refer to section 4 / for explanations of how cables/wires should be connected, according to wire
color code.
IP65
!
Figure 11: Cable preparation : cable position for water tightness
Cable for wiring shall be AWG 20 to 24, length shall be adapted to the size of the hole in the wall, to
terminal connections, and to the distance between the electric source and the terminal itself.
For power supply, IDEMIA recommends using a 24V power supply and AWG16 gauge cable.
To ensure water tightness, be sure to bend the cable downward.
For test purpose, it is possible to use the existing connector without cutting it. This connector mates with
Molex PCB header reference 5016452620. The pinout of this connector is described in this document in
section 4 /.
The pinout indications that you can see on the labels of the cable shall NOT be taken into
account as they correspond to the OTHER connector on the device side. Please use only
the pinout information given in this document in section 4 /.