Installation Guide

52
VisionPass - 2019_2000045728
RS485
10 Green / Black RS485_RX_A In/Out RS485 Rx/Tx non inverting signal
8 Green / White RS485_RX_B In/Out RS485 Rx/Tx inverting signal
11 Black / Red RS485_GND Ground
Figure 26: Serial port wiring – RS485
RS485 implementation is limited to half-duplex communication. So only Tx+, Tx- and ground reference
signals are necessary.
Depending on the RS485 network, an impedance adaptation may be required.
For farthest terminal, a 120-Ohms resistor termination may be added outside the terminal between TX+
and TX-.
RS422
7 Blue / Black RS422_RX_A In RS422 non inverting Receive
9 Blue / White RS422_RX_B In RS422 inverting Receive
10 Green / Black RS422_TX_Y Out RS422 non inverting Transmit
8 Green / White RS422_TX_Z Out RS422 inverting Transmit
11 Black / Red RS422_GND Ground
Figure 27: Serial port wiring – RS422
RS422 interface is a full duplex communication.