Installation Guide
54
VisionPass - 2019_2000045728
4.9 > Ethernet connection
Use a category 6 shielding cable (120 Ohms) or better. It is strongly recommended to insert a repeater
unit every 90 m.
Recommendations for RJ45 wiring
Pin 1 2 3 4 5 6 7 8
Signals
Data
pair 1
Data
pair 1
Data
pair 2
NC/POE
pin
dedicated
(+)
NC/POE
pin
dedicated
(+)
Data
pair 2
Ground/
pin
dedicated
(-)
NC/POE
pin
dedicated
(-)
EIA / TIA T568B
Colors
White
orange
Orange
White
green
Blue White blue Green
White
brown
Brown
EIA / TIA T568A
Colors
White
green
White
green
White
green
White
green
White
green
White
green
White
green
White
green
Corel L120
Colors
Grey White Pink Orange Yellow Blue Purple Brown
Figure 30: RJ45 wiring
RJ45 plug pinout is compliant with 10/100 base T, IEEE802.3 Specification. Product is compliant also with
MDI or MDI-X.
Ethernet cable shall be shielded
Default Ethernet configuration
By default, VisionPass terminal is configured in STATIC mode with the following configuration: IP Adress
: 192.168.1.10; Gateway Adress : 192.168.1.254; Subnet Mask : 255.255.254.0