2.1.1  LF Limitations for ATEX 
Due to Barrier (VCL1520) and cable series resistance, it is not possible to operate LF with full power and 12 slots 
all the time. Therefore, LF operation is limited by firmware according to the slot scheme and the restrictions below. 
LF slot settings depending on configured LF power: 
Configured LF 
power 
Minimum Delay 
between LF 
telegram  
Minimum 
Cycle delay  
Description 
0 to 39%  0 ms  10 ms  All slots active 
40% to 59%  40 ms  10 ms  Only 6 slots per frame are active  
(1 slot inactive between 2 actives slots) 
60% to 79%  100ms  10 ms  Only 2 slots actives per frame 
(5 slots inactive between 2 actives slots) 
80% to 100%  500 ms  250 ms  Only 1 slot per double frame is active 
ATTENTION: This is just an example. If you have other parameters, additional cable length or other voltage drops 
between the Barrier and the iPOINT X the settings mentioned above will differ and can end in improper operation of 
LF or even the whole device.   