“Testing” Menu:
Several test possibilities are available in this menu. i-PORT operation is put on hold during
test mode (operation will resume after leaving test mode). The settings from the
Configuration Page (antenna settings, slots, etc.) apply here also.
Miscellaneous Settings:
Tag Type: i-Q8/32
Ant: Send antenna during test mode (for receive antenna, see Configuration)
Loop: Operation takes place in closed-loop action
Pressing the SCAN button triggers a scan. If tags are located in the zone, a list of these tags
will be displayed. Clicking on a tag selects that Tag ID (see “Tag-ID” field). Consequently,
data can be exchanged with this tag.
Session Setup: This command determines battery voltage (mV), i.e. tag status (tag
blinks).
Write EEPROM: Data can be written to the tags using this command. Enter the desired
address into the “Address” field; enter the data into the “Data” field
(Length = Amount/No. of Data Items).
Read EEPROM: Data can be read from the tags using this command. In the “Address”
field, enter the address FOLLOWING WHICH the data should be read.
Temp. Logging: Temperature progression of a temperature tag can be displayed using this
command. First execute “Session Setup”, and then click on “Temp.
Logging”! (Prerequisite: temperature tag; tag must have activated
Logger!)
Writeable Data Range for Tags (decimal):
Tag Type Start Address Stop Address Start Address Stop Address
i-Q8 132 8191
i-Q8T 132 5887 6144 8191
i-Q32T 132 5887 6144 32767