3.3 Overview
Position
Server
Ethernet
or RS422 (i-BUS)
i-PORT M 350 RTLS
i-PORT M 350 RTLS
i-BUS i-BUS
Central Power Supply
i-PORT M 350 RTLS
3.4 Power Supply
The i-PORT M 350 RTLS is powered by the i-BUS.
Total Power Consumption—i-PORT M 350 RTLS with 4 i-SAT 300 RTLS
1 × i-PORT M 350 RTLS, app. 2 W
4 × i-SAT 300 RTLS, app. each 2 W
This gives a maximum sum of 7 W of power consumption.
3.5 Maximum Overall Cable Runs of i-BUS
There are 2 general limitations on the length of the i-BUS cabling:
The overall length of the i-BUS over all units on the BUS must not exceed 1000 m (3000 ft)
The distance from one unit to the next on the i-BUS must not exceed 300 m (1000 ft)
This tables is valid for Cat 5 cabling with gauge diameters of AWG24 (0.25 mm²).
# of i-PORTs Length (m/ft) Remark
1 300/1000 Central supply with 24 VDC via the i-BUS
2 600/2000 Central supply with 24 VDC via the i-BUS
3 400/1300 Central supply with 24 VDC via the i-BUS
4 250/820 Central supply with 24 VDC via the i-BUS
4 1000/3000 GND potential free power supplies at every i-PORT M