User's Manual

PAC2111 Operation / Installation Manual
IDT
.QM.P
2
.T1.DT
VER
1.1
Page
6
9
Printed copies of this document are uncontrolled
Internal Use Only
4.2 Recommended Infrastructure
Wiegand cable ( 11 core** + Drain , 22AWG for 500Ft or 24AWG for 300Ft )
Linear DC power Supply 5-16 V, 1A min.
** Note: The number of cores on the cable can vary depending on the actual field requirement. On a
minimum 6 Cores + Drain is recommended (Power 2, Wiegand outputs -2, Wiegand Inputs- 2)
4.3 Specifications
Model Number Op Voltage Current Op temp Cable Length
PAC2111 5-16 V Dc Av -130mA
Pk -200mA
-35 to +70Deg C
RS485 - 4000Ft
Wiegand -500ft (22AWG)
300ft (24AWG)
4.4 Wiring Information
Pig Tail Cable Color
Function
RED + VDC
Black GND
Green Wiegand output D0
White Wiegand output D1
Orange Wiegand Green LED Input
Yellow Wiegand Buzz Input
Blue Input2
Brown Input1
Grey RS485 -
Pink RS485 +
Violet Tamper Output
Black Shrink Tube Drain Wire
Caution:
During Wiring make sure that the +VDC lines does not make contact with any other cables, as it might
affect reader functionality/ cause damage to the reader.