PAT 1111 Installation Manual Rev 1.
Package Details • • • • PAT 1111 Mounting plate and screws Test card (contactless) Installation manual Recommendations • • • Cable, 10 conductor (Wiegand/Magstripe), 22GA Shielded, Upto 150 mtrs, Line Resistance 2.
Installation Instructions • • Fix the mounting plate in an appropriate position on the wall, where the cable can be easily connected to the back of the reader. Place the reader on the mounting plate and fix it by using mounting screw. This is shown in the picture below.
Mounting plate details Fig 1.1 Mounting plate (Horizontal view) Fig 1.2 Mounting plate (Normal view) PAT 1111 Installation Manual Fig 1.
Connector details Connector details for Wiegand/Magstripe – 10pin Terminal Block Pin Number 1 2 3 4 5 6 7 8 9 10 Signal Name Relay IN1 Relay IN2 Relay IN3 Relay GND Wiegand Data0 / Mag Data Wiegand Data1 / Mag CLK Wiegand LED IN Wiegand Buzzer IN Wiegand GND Wiegand +12V Connector details for RS485 – 8pin Terminal Block Pin Number Signal Name (Full Duplex Operation ) Signal Name (Half Duplex Operation) 1 2 3 4 5 6 7 8 RX_A RX_B TX_A TX_B RS485 GND SHIELD Power +12V Power GND RX/TX_A RX/TX_B No conne
Photographs of the Reader Front view Rear view Access Granted/Denied Indication LED Contactless LED 10 pin terminal block for Wiegand/Magstripe 8 pin terminal block for RS485 Contactless field RS485 DIP switch Testing • • • • Connect the reader to the host through Wiegand/Magstripe/RS485 interface. Switch on the power to the reader and check if the contactless LED glows. This signifies that the reader is ready. Wave the test contactless card in front of the reader.