User Manual uTrust TS Contact WallMount Reader 8116 Version 1.0 Confidential Author Version Date Document no Sixtus Stanly 1.
Document History Version 1.
uTrust TS Contact Wallmount Reader Contents 1.0 Introduction ................................................................................................................................ 4 2.0 Reader ......................................................................................................................................... 4 2.1 2.2 2.3 Functionality ..............................................................................................................................
uTrust TS Contact Wallmount Reader 1.0 Introduction This document details the Physical Access Control Reader uTrust TS Contact Wallmount Reader and its basic user instruction and installation procedures. The 8116 reader extends the features supported by the 8110 readers, by adding interfaces for accessing a Contact Smart Card and a SAM interface. The contact interface enables users to securely access their contact smart cards.
uTrust TS Contact Wallmount Reader 2.
uTrust TS Contact Wallmount Reader 2.
uTrust TS Contact Wallmount Reader Rear View with Backplate Back plate Page 7 of 15
uTrust TS Contact Wallmount Reader 3.0 Product details Model Name : 8116 Device Type : RFID reader, 13.56MHz (HF) / 125 KHz (LF), with Contact smartcard Slot for ID-1 sized cards and SAM slot.
uTrust TS Contact Wallmount Reader 6.0 Product Certification ID’s 6.1 FCC Certification ID – MBPTSWMSC-00 6.2 IC Certification ID – 7485A-TSWMSCR0 7.0 Installation details Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the authorities having jurisdiction. 7.1 Parts List • • • • • • • 7.2 TS Contact Wallmount reader -1 Screws (A #6-18X1.
uTrust TS Contact Wallmount Reader 7.3 Connector Information 7.3.1 - Pinout diagram Shield Ground/ Drain – Black wire should be connected to the cable shield. Caution: During Wiring make sure that the +VDC lines does not make contact with any other cables, as it might affect reader functionality/ cause damage to the reader.
uTrust TS Contact Wallmount Reader 7.4 7.4.
uTrust TS Contact Wallmount Reader 7.4.2 Reader Installation Steps a. Make the required holes on the wall as per the backplate drawing above. b. The reader is to be mounted at a height less than 2 meters from the floor for MS1 compliance as per IEC 62368-1 c. Insert the nylon screw plugs into the wall. d. Connect the wires as per the Table 2 or Table 3. e. Secure the backplate onto the wall using the Screws (A #6-18X1.5" SS ) f. Hook the reader onto the backplate g.
uTrust TS Contact Wallmount Reader Power up and Testing 8.
uTrust TS Contact Wallmount Reader Page 14 of 15
uTrust TS Contact Wallmount Reader 9.0 Certifications 9.1 FCC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.