User Manual

26 27
STEP 5
Turn the power back ON at the breaker. Using your voltage detector,
identify which of the two wires you removed from the common
terminal is energized. This is the “line” wire. Mark this wire as the
Secondary (S) Switch Position. You will need to refer to this during the
Wireless Communication Setup.
The wire you removed from the common terminal that is not
energized is the “load” wire. Mark as the Primary (P) Switch Position.
You will need to refer to this during the Wireless Communication Setup.
NOTE: Your home’s wiring may differ; please consult a qualied electrician.
S
P
TRAVELER
(Usually Black or Red)
GROUND
(Usually Bare Copper or Green)
NEUTRAL
(Usually White)
GROUND
(Usually Bare Copper or Green)
TRAVELER
(Usually Black or Red)
COMMON
TERMINAL
COMMON
TERMINAL
LINE
(Usually Black)
LOAD
(Usually Black)