Datasheet
IDITECH CORPORATION
SPECIFICATION
TITLE SPC. NO.
PAGE: 1 OF 4
MINI DIN JACK
DATE: 2013.04.24
SPECIFICATION
1. Standard atmospheric condition
Unless otherwise specified, the standard range of atmospheric conditions for making measurements
and tests is as follows:
Ambient temperature﹕5℃ to 35℃
Relative humidity ﹕45% to 85%
Air pressure ﹕86kPa to 106kPa
Operating temperature range﹕-40℃ to 85℃
Storage temperature range ﹕-40℃ to 85℃
2. Electrical characteristics
Item Conditions Specifications
2.1 Rated voltage/
Rated current
AC 100V 1A
Or
DC 12V 2A MAX.
2.2 Dielectric
strength
Between conductors which should not make
contact under normal conditions.
250V AC r.m.s(50 to 60Hz)for 1 min.
(trip current 2mA)
Without breakdown
2.3 Insulation
resistance
A voltage of 250V DC shall be applied for a
minute. Between conductors which should not
make contact under normal conditions after
which measurement shall be made.
50MΩ MIN.
2.4 Contact resistance
Measurement shall be made
at 1000Hz with
small
current:50mA
Pin-Contact:30mΩ MAX.
Plug cover-Socket:
50mΩ MAX.
ISSUE DATE WRTN CHKD
APVD DESCRIPTIONS
2013.04.24
JON JON ELVIS
S-JACK/001