6. SMART-70 Specifications
6.1 SMART-70 Input Hopper
Capacity
Card
Max. 500 cards
Feeding
Automatic
Card
Size
ISO CR80 (54mm x 86mm / 2.12” x 3.38”)
Thickness
0.38mm (15mil), 1.2mm (47mil)
Type
PVC, Composite PVC, PET
Sensor
Residual Q’ty Sensor
Near Empty & Empty
Detection Sensor
Cartridge Mount Status Detectable
System
Communication
RS-485, RS-232C
Power Supply(Adapter)
DC 24V, 2A
Temp. / Humidity
15~35℃ / 35~70%
Security
Physical Lock
Cartridge
Station Itself
Kensington Lock
Dimensions
Millimeter
170 (W) x 204 (L) x 548 (H)
Inch
6.7 (W) x 8.0 (L) x 21.6 (H)
Weight
Kg/lbs.
Approx. 3.7 kg / 8.2 lbs.
6.2 SMART-70 Encoding Station
Encoding Sensor
Magnetic
ISO 7811 (Track I, II, III Read/Write, HiCo/LoCo), JIS II
Contact
ISO 7816 (ID-1)
Contactless
MIFARE, ISO 1443(Type A/B), ISO 15693, DEFIRE, iCLASS
Barcode Reader
1D & 2D Barcode Reader (Front/Back)
System
Communication
USB, RS-232C
Power Supply
Free Voltage (AC100 / 220V, 50~60Hz)
Power Supply(Adapter)
DC 24V, 2A
Temp. / Humidity
15~35℃ / 35~70%
Security
Physical Lock
Encoding Station
Station Itself
Kensington Lock
Dimensions
Millimeter
240 (W) x 214 (L) x 305 (H)
Inch
9.5 (W) x 8.4 (L) x 12 (H)
Weight
Kg/lbs.
TBD