IDentification with Radio and Optical
6. 1 Environmental Specifications
Table 6-1 : Environmental Specifications
Parameter
Description
Operating Temperature
-20 ~55
Storage Temperature
-30 ~85
Humidity
5~95%RH
Case Material
Aluminum
ESD immunity (Air discharge)
(Contact discharge)
±8 kV EN6100-4-2
±4 kV
Case Dimensions
135.9 x 126.4 x 35 mm
Weight
580g
6. 2 Power Supply Specifications
Table 6-2 : Power Supply Specifications
Parameter
Description
Input Voltage
100 ~ 240 Vac
Input Current
1.3A max.
Input Frequency
50 ~ 60 Hz
Output Voltage
12Vdc
Output Current
3A max.
6. 3 Reader Specifications
VCC=12V, typical values at 25, unless otherwise noted.
Table 6-3 : Reader Specifications
Parameter
Min.
Typ.
Max.
Unit
Conditions
Supply Current
(Active mode)
800
mA
Transmit Power : +30dBm
Supply Current
(Standby mode)
100
mA
RX input impedance
50
RX sensitivity
-74
dBm
TX Power
+5
+30
dBm
Frequency
860
960
MHz
See Appendix A
Channel bandwidth
200
kHz