User's Manual

IDRO900F User's Manual
24
IDentification with Radio and Optical
Connection Diagram
Use Power from external devices (LAMP or Buzzer) for power(V+,V-).
Select a product with an external device voltage of 5 to 24 VDC.
5~24VDC
Tower Lamp
(ST45B-1-12-R)
BLACK
LAMP : RED
or
BUZZER : BROWN
[Figure 6.5.2 ] IDRO900F GPIO Output Connections
Operating method
. Click Properties on the Reader@Express Click GPIO and set the Output like below Apply
Close
> OUTPUT LEVEL : Display the output level status before Inventory.
- L : Lamp or BUZZER OFF
- H : Lamp or BUZZER ON
> OUTPUT FLASH : Display the output level status when tag reading after Inventory.
- L : Lamp or BUZZER OFF
- H : Lamp or BUZZER ON
- Duration (msec) : Set the Lamp or Buzzer on/off time.
> If OUTPUT LEVEL and OUTPUT FLASH are set as shown above, when LAMP is connected to GPIO
output 1 port, it operates as follows.