IDentification with Radio and Optical
Select a product with an external device voltage of 5 to 24 VDC.
Photo sensor must use the NPN open collector output. (example: BA2M-DDT, BJX1M-DDT....)
POWER ()
Photo sensor
(BA2M-DDT)
(BJX1M-DDT)
BLACK
BROWN
BLUE
[Figure 6.5.3 ] IDRO900F GPIO Input Connections
Operating method
. Clinck Properties on the Reader@Express Click GPIO and set the Input like below Apply
Close
> If INPUT DETECT is set as above and the DC Level changes to HL or LH in GPIO input 1,
the reader performs Inventory operation.
(2) GPIO Input & output
In the parking management system, when a sensor is detected in the GPIO input, the reader operates
and is used in the application system to open and close the door by outputting a signal to the GPIO
output during tag reading.
Operating method
. Click Properties on the Reader@Express Click GPIO and set the Input & Output like below
Apply Close