User's Manual

AM600 Ver. 1.0 User Manual
Mod: MDM/011/M2 Rev 6
IDS GeoRadar Srl User Manual MNG/2020/001 Rev. 1.0 10/ 17
Fig. 6 - Connection of AM600 GPR unit
5. Press the power on button.
6. Operate the GPR unit, with the use of provided IDS Georadar’s
software, according the survey the user intends to perform (please,
refer to specific software product User Manual).
6 TECHNICAL SPECIFICATIONS
Data
Measure
Size
333 mm x 258 mm x 142 mm (h)
Weight
2.35 kg
Power supply
12V DC
Power consumption
5.5 W
Input ports
19 pin connector + 4 pin connector
Output ports
19 pin connector
Communication ports
Ethernet 100 baseT
Transmitting elements
2
Receiving elements
2
Environmental
IP65
Operational temperature range
-20 - +40 °C
Junction box
Ethernet cable
12V lead battery
Battery cable
Power ON