User's Manual

IDS Ingegneria Dei Sistemi S.p.A. Protocol: MN/2009/030 - Rev. 1.2
Safe Rail System Data Acquisition Software
36
/
76
Fig. 4-7 – Gain calibration underway
3.
You can check in the sweep display window that each antenna displays a
radar signal (see Fig. 4-8); this display window is found in Fig. 4-7.
Fig. 4-8 – Controlling the presence of radar signal on the antenna/s
!
NOTE
A lack of signal in the window shown in Fig. 4-8
should warn you that
the system is not operating
4.
You can skip this phase by pressing the button shown in
Fig. 4-7, but this means that you can only review pre-existing radar data,
and not acquire new data.
5.
Pressing the button opens the window shown in Fig.
4-9, from where you can edit, delete or create a new gain calibration file.