Fig. 4-9 –Calibration file selection window
Pressing the
New
button from the window of Fig. 4-9 opens the window
shown in Fig. 4-10 from where you can edit the calibration filename. Now
press the
OK
button to open the window shown in Fig. 4-11, from where you
can set the gain values to apply on the radar map.
Fig. 4-10 – Gain window
The following parameters can be set in the window shown in Fig. 4-11
the time in nsec in the
Time
column,
the value of gain to apply on the radar map based on the values set in the
Gain
column.
Then pressing the
Apply
button, you can draw the gain curve based on these
values.
As an alternative to the above procedure, you can use the graphics mode,
which consists of manually inserting the individual points of the gain curve.
To activate this procedure:
o
point with the mouse on the red square on the right edge of the
window, corresponding to the value 0dB (Fig. 4-12 and Fig. 4-13)