Example
AP SEND MCU RAED Voltage Command:
AP->MCU
:
Command<02><01><09><0C><0D>
STX0x02 Length0x01 Command0x09 CR0x0D
Checksum0x020x010x09MOD 0x100 0x0C
MCU Response AP Voltage Value:
MCU->AP:
Response<02><03><09><3E><80><CC><0D>
STX0x02 Length0x03 Command0x09 Data0x3E80 CR0x0D
Checksum0x020x030x090x3E0x80MOD 0x100 0Xcc
Return Value:0x3E80(16000mV)
AP SEND MCU RAED IP Address Command:
AP->MCU
:
Command<02><01><50><53><0D>
STX0x02 Length0x01 Command0x50 CR0x0D
Checksum0x020x010x50MOD 0x100 0x53
MCU Response AP IP Address:
MCU->AP:
Response<02><05><50><A9><FE><01><01><00><0D>
STX0x02 Length0x05 Command0x50 Data1:0xA9
Data2:0xFE Data3: 0x01 Data4 :0x01 CR0x0D
Checksum0x020x050x500xA90xFE0x010x01MOD 0x100 0x00
Return IP Address: A9: FE: 01: 01
AP SEND MCU Write IP Address Command:
AP->MCU:
Command+ data<02><05><51><A9><FE><01><01><01><0D>
STX0x02 Length0x05 Command0x51 Data1:0xA9
Data2:0xFE Data3: 0x01 Data4 :0x01 CR0x0D
Checksum0x020x050x51 0xA90xFE 0x01 0x01MOD 0x1000x01