ICE-PV-N4551_D5251 COM Express Type 2 Module IEI Technology Corp. MODEL: ICE-PV-N4551/D525 COM Express Module (Type 2) Intel® ATOM CPU RoHS Compliant User Manual Page i Rev. 1.
ICE-PV-N4551_D5251 COM Express Type 2 Module Revision Date Version Changes 3 April, 2012 1.02 Minor correction to Table 3-1: ICE-PV-N4551/D5251 Interface Connectors and Section 3.2 Peripheral Interface Connectors 14 February, 2012 1.01 Minor correction to Table 3-3: COM Express Connector AB Pin Definitions and Section 1.5 Technical Specifications 27 September, 2011 Page ii 1.
ICE-PV-N4551_D5251 COM Express Type 2 Module Copyright COPYRIGHT NOTICE The information in this document is subject to change without prior notice in order to improve reliability, design and function and does not represent a commitment on the part of the manufacturer. In no event will the manufacturer be liable for direct, indirect, special, incidental, or consequential damages arising out of the use or inability to use the product or documentation, even if advised of the possibility of such damages.
ICE-PV-N4551_D5251 COM Express Type 2 Module Packing List NOTE: If any of the components listed in the checklist below are missing, please do not proceed with the installation. Contact the IEI reseller or vendor you purchased the ICE-PV-N4551/D5251 from or contact an IEI sales representative directly. To contact an IEI sales representative, please send an email to sales@iei.com.tw The items listed below should all be included in the ICE-PV-N4551/D5251 package.
ICE-PV-N4551_D5251 COM Express Type 2 Module Table of Contents 1 INTRODUCTION.......................................................................................................... 1 1.1 OVERVIEW.................................................................................................................. 2 1.1.1 Applications ....................................................................................................... 2 1.1.2 Benefits.........................................................
ICE-PV-N4551_D5251 COM Express Type 2 Module 4.1 INSTALLATION CONSIDERATIONS .............................................................................. 31 4.2 UNPACKING .............................................................................................................. 32 4.2.1 Unpacking Precautions.................................................................................... 32 4.2.2 Checklist...............................................................................................
ICE-PV-N4551_D5251 COM Express Type 2 Module 5.4 CHIPSET ................................................................................................................... 60 5.4.1 Host Bridge Configuration .............................................................................. 61 5.4.2 South Bridge Configuration............................................................................. 63 5.4.3 Intel IGD SWSCI OpRegion.............................................................................
ICE-PV-N4551_D5251 COM Express Type 2 Module List of Figures Figure 1–1: ICE-PV-N4551/D5251 ..................................................................................................2 Figure 1-2: Front View (mm) ..........................................................................................................4 Figure 1-3: Side Dimensions (mm) ...............................................................................................5 Figure 1-4: Data Flow Block Diagram .................
ICE-PV-N4551_D5251 COM Express Type 2 Module List of Tables Table 1-1: Technical Specifications............................................................................................10 Table 2-1: Package List Contents ...............................................................................................14 Table 3-1: ICE-PV-N4551/D5251 Interface Connectors .............................................................17 Table 3-2: COM Express Connector CD Pin Definitions........................
ICE-PV-N4551_D5251 COM Express Type 2 Module BIOS Menus BIOS Menu 1: Main .......................................................................................................................40 BIOS Menu 2: Advanced ..............................................................................................................42 BIOS Menu 3: ACPI Settings .......................................................................................................42 BIOS Menu 4: CPU Configuration ................
ICE-PV-N4551_D5251 COM Express Type 2 Module Chapter 1 1 Introduction Page 1
ICE-PV-N4551_D5251 COM Express Type 2 Module 1.1 Overview Figure 1–1: ICE-PV-N4551/D5251 The ICE-PV-N4551/D5251 COM Express module provides the main processing chips and is connected to a compatible COM Express carrier board. The ICE-PV-N4551/D5251 is equipped with an Intel® Atom™ N455/D525 CPU, Intel® Atom™ N455/D525 Northbridge and Intel® ICH8M Southbridge and provides multiple modern serial I/O options, while offering limited support for legacy I/Os.
ICE-PV-N4551_D5251 COM Express Type 2 Module 1.1.2 Benefits Some of the ICE-PV-N4551/D5251 embedded platform benefits include: Low power, high performance Easy integration into customized baseboards Easy upgrading Easy maintenance Easy design compatibility Low cost product development 1.1.
ICE-PV-N4551_D5251 COM Express Type 2 Module 1.2 Dimensions The dimensions of the board are listed below: Length: 95 mm Width: 95 mm 1.2.1 Top View The figure below shows the dimensions from the top view.
ICE-PV-N4551_D5251 COM Express Type 2 Module 1.2.2 Side View The figure below shows the dimensions as viewed from the side.
ICE-PV-N4551_D5251 COM Express Type 2 Module 1.3 Data Flow Figure 1-4 shows the data flow between the two on-board chipsets and other components installed on the motherboard and described in the following sections of this chapter.
ICE-PV-N4551_D5251 COM Express Type 2 Module 1.4 Connectors The ICE-PV-N4551/D5251 embedded module has the following connectors as seen in Figure 1-5 and Figure 1-6.
ICE-PV-N4551_D5251 COM Express Type 2 Module Figure 1-6: ICE-PV-N4551/D5251 Overview (Reverse Side) 1.4.1 IO Interface Support The ICE-PV-N4551/D5251 embedded module supports the following IO interfaces on the baseboard: Page 8 1 x IDE channel (signal to base board) 3 x SATA 3Gb/s (to base board) 8 x USB 2.
ICE-PV-N4551_D5251 COM Express Type 2 Module HD Audio (through HD audio chip on the baseboard, connected to HD audio interface on the ICE-PV-N4551/D5251) Legacy ports (COM, LPT, BIOS, and PS/2) through super I/O on the baseboard connected to the LPC interface on the ICE-PV-N4551/D5251. 1.5 Technical Specifications ICE-PV-N4551/D5251 technical specifications are listed in Table 1-1. Detailed descriptions of each specification can be found in the detailed specifications chapter.
ICE-PV-N4551_D5251 COM Express Type 2 Module Specification Value Watchdog Timer Software programmable supports 1~255 sec.
ICE-PV-N4551_D5251 COM Express Type 2 Module Chapter 2 2 Unpacking Page 11
ICE-PV-N4551_D5251 COM Express Type 2 Module 2.1 Anti-static Precautions WARNING: Failure to take ESD precautions during the installation of the ICE-PV-N4551/D5251 may result in permanent damage to the ICE-PV-N4551/D5251 and severe injury to the user. Electrostatic discharge (ESD) can cause serious damage to electronic components, including the ICE-PV-N4551/D5251. Dry climates are especially susceptible to ESD.
ICE-PV-N4551_D5251 COM Express Type 2 Module 2.3 Unpacking Checklist NOTE: If some of the components listed in the checklist below are missing, please do not proceed with the installation. Contact the IEI reseller or vendor you purchased the ICE-PV-N4551/D5251 from or contact an IEI sales representative directly. To contact an IEI sales representative, please send an email to sales@iei.com.tw. 2.3.
ICE-PV-N4551_D5251 COM Express Type 2 Module Quantity Item 1 Utility CD Table 2-1: Package List Contents Page 14 Image
ICE-PV-N4551_D5251 COM Express Type 2 Module Chapter 3 3 Connectors Page 15
ICE-PV-N4551_D5251 COM Express Type 2 Module 3.1 Peripheral Interface Connectors Section 3.1.1 shows interface connector locations. Section 3.1.2 lists all the interface connectors seen in Section 3.1.1. 3.1.1 ICE-PV-N4551/D5251 Layout Figure 3-1 shows the on-board peripheral connectors, backplane peripheral connectors and on-board jumpers.
ICE-PV-N4551_D5251 COM Express Type 2 Module Figure 3-2: Connector and Jumper Locations (Back Side) 3.1.2 Peripheral Interface Connectors Table 3-1 shows a list of the interface connectors on the ICE-PV-N4551/D5251 Detailed descriptions of these connectors can be found in Section 3.2.
ICE-PV-N4551_D5251 COM Express Type 2 Module 3.2 Peripheral Interface Connectors The location of the pins and the pinout descriptions of the peripheral interface connectors are given below. 3.2.1 COM Express Connector CD CN Label: J4 CN Type: 220-pin COM Express connector CN Location: See Figure 3-3 CN Pinouts: See Table 3-2 The standard COM Express connector locations and pinouts are shown below.
ICE-PV-N4551_D5251 COM Express Type 2 Module Pin No. Description Pin No.
ICE-PV-N4551_D5251 COM Express Type 2 Module Pin No. Description Pin No.
ICE-PV-N4551_D5251 COM Express Type 2 Module Pin No. Description Pin No.
ICE-PV-N4551_D5251 COM Express Type 2 Module Pin No. Description Pin No.
ICE-PV-N4551_D5251 COM Express Type 2 Module Figure 3-4: COM Express Connector AB Location Pin No. Description Pin No.
ICE-PV-N4551_D5251 COM Express Type 2 Module Pin No. Description Pin No.
ICE-PV-N4551_D5251 COM Express Type 2 Module Pin No. Description Pin No.
ICE-PV-N4551_D5251 COM Express Type 2 Module Pin No. Description Pin No.
ICE-PV-N4551_D5251 COM Express Type 2 Module Pin No. Description Pin No. Description A109 +V12 B109 +V12 A110 GND B110 GND Table 3-3: COM Express Connector AB Pin Definitions 3.2.3 SO-DIMM Connector CN Label: DIMM1 CN Type: SO-DIMM connector CN Location: See Figure 3-5 The SO-DIMM socket is for installing SO-DIMM memory. Figure 3-5: SO-DIMM Connector Location 3.2.
ICE-PV-N4551_D5251 COM Express Type 2 Module CN Type: 6-pin connector CN Location: See Figure 3-6 CN Pinouts: See Table 3-4 The SPI connector is for flashing new BIOS onto the SPI BIOS chip. Figure 3-6: SPI Flash Connector Location Pin No.
ICE-PV-N4551_D5251 COM Express Type 2 Module Pin No. Description 6 SPI_VCC (+3.
ICE-PV-N4551_D5251 COM Express Type 2 Module Chapter 4 4 Installation Page 30
ICE-PV-N4551_D5251 COM Express Type 2 Module 4.1 Installation Considerations NOTE: The following installation notices and installation considerations should be read and understood before the CPU module is installed. All installation notices pertaining to the installation of the CPU module should be strictly adhered to. Failing to adhere to these precautions may lead to severe damage of the CPU module and injury to the person installing the CPU module.
ICE-PV-N4551_D5251 COM Express Type 2 Module 4.2 Unpacking NOTE: If any of the items listed below are missing when the ICE-PV-N4551/D5251 is unpacked, do not proceed with the installation and contact the ICE-PV-N4551/D5251 reseller or vendor. 4.2.1 Unpacking Precautions Before installing the ICE-PV-N4551/D5251, unpack the CPU module. Some components on ICE-PV-N4551/D5251 are very sensitive to static electricity and can be damaged by a sudden rush of power.
ICE-PV-N4551_D5251 COM Express Type 2 Module If one or more of these items are missing, please contact the reseller or vendor the ICE-PV-N4551/D5251 was purchased from and do not proceed any further with the installation. 4.3 SO-DIMM Installation To install a SO-DIMM into a SO-DIMM socket, please follow the steps below and refer to Figure 4-1. Figure 4-1: SO-DIMM Installation Step 1: Locate the SO-DIMM socket. Place the ICE-PV-N4551/D5251 on an anti-static pad. Step 2: Align the SO-DIMM with the socket.
ICE-PV-N4551_D5251 COM Express Type 2 Module 4.4 Jumper Settings NOTE: A jumper is a metal bridge used to close an electrical circuit. It consists of two or three metal pins and a small metal clip (often protected by a plastic cover) that slides over the pins to connect them. To CLOSE/SHORT a jumper means connecting the pins of the jumper with the plastic clip and to OPEN a jumper means removing the plastic clip from a Jumper Locations jumper.
ICE-PV-N4551_D5251 COM Express Type 2 Module 4.4.1 LVDS Panel Resolution Jumper Label: SW1 Jumper Type: 4-in-1 switch Jumper Settings: See Table 4-2 Jumper Location: See Figure 4–2 This switch sets the resolution of the panel attached to the LVDS output. Settings are shown in Table 4-2.
ICE-PV-N4551_D5251 COM Express Type 2 Module WARNING! Please note that the installation instructions described in this manual should be carefully followed in order to avoid damage to the CPU module components and injury to the user. WARNING! When installing electronic components onto the embedded module or installing the embedded module onto the baseboard, always take anti-static precautions in order to prevent ESD damage to the CPU module and other electronic components like the CPU and SO-DIMM module.
ICE-PV-N4551_D5251 COM Express Type 2 Module Chapter 5 5 BIOS Setup Page 37
ICE-PV-N4551_D5251 COM Express Type 2 Module 5.1 Introduction NOTE: The BIOS items shown below are from an ICE-PV-N4551/D5251 installed on the ICE-DB-9S-R10 reference carrier board. The ICE-DB-9S-R10 reference carrier board is available from iEi, contact sales@iei.com.tw or go to http://www.ieiworld.com for more information. The BIOS is programmed onto the BIOS chip. The BIOS setup program allows changes to certain system settings. This chapter outlines the options that can be changed. 5.1.
ICE-PV-N4551_D5251 COM Express Type 2 Module Key Function Right arrow Move to the item on the right hand side + Increase the numeric value or make changes - Decrease the numeric value or make changes Page up Move to the next page Page down Move to the previous page Esc Main Menu – Quit and do not save changes into CMOS Status Page Setup Menu and Option Page Setup Menu -Exit current page and return to Main Menu F1 General help, only for Status Page Setup Menu and Option Page Setup Menu F9 Lo
ICE-PV-N4551_D5251 COM Express Type 2 Module Security – Sets User and Supervisor Passwords. Save & Exit – Selects exit options and loads default settings The following sections completely describe the configuration options found in the menu items at the top of the BIOS screen and listed above. 5.2 Main The Main BIOS menu (BIOS Menu 1) appears when the BIOS Setup program is entered. 3 The Main menu gives an overview of the basic system information.
ICE-PV-N4551_D5251 COM Express Type 2 Module The System Overview field also has two user configurable fields: System Date [xx/xx/xx] Use the System Date option to set the system date. Manually enter the day, month and year. System Time [xx:xx:xx] Use the System Time option to set the system time. Manually enter the hours, minutes and seconds. 5.
ICE-PV-N4551_D5251 COM Express Type 2 Module Aptio Setup Utility – Copyright (C) 2011 American Megatrends, Inc. Main Advanced Chipset Boot Security Save & Exit > > > > > > > > ACPI Settings CPU Configuration IDE Configuration USB Configuration F75387 HardWare Monitor Secondary Super IO Configuration WinBond W83627EHG HardWare Monitor Serial Port Console Redirection System ACPI Parameters. ---------------------- : Select Screen : Select Item Enter Select +/-: Change Opt.
ICE-PV-N4551_D5251 COM Express Type 2 Module ACPI Sleep State [S1 (CPU Stop Clock)] Use the ACPI Sleep State option to specify the sleep state the system enters when it is not being used. S1 (CPU DEFAULT Stop Clock) The system enters S1 (POS) sleep state. The system appears off. The CPU is stopped; RAM is refreshed; the system is running in a low power mode. S3 The caches are flushed and the CPU is powered off. (Suspend to Power to the RAM is maintained.
ICE-PV-N4551_D5251 COM Express Type 2 Module Processor Type: Lists the brand name of the CPU being used EMT64: Indicates if the EM64T is supported by the CPU.
ICE-PV-N4551_D5251 COM Express Type 2 Module 5.3.3 IDE Configuration Use the IDE Configuration menu (BIOS Menu 5) to change and/or set the configuration 3 of the IDE devices installed in the system. Aptio Setup Utility – Copyright (C) 2011 American Megatrends, Inc. Advanced PATA Master PATA Slave Not Present Not Present Select ATA or IDE configuration.
ICE-PV-N4551_D5251 COM Express Type 2 Module Configures SATA devices as AHCI device. AHCI 5.3.4 USB Configuration Use the USB Configuration menu (BIOS Menu 6) to read USB configuration information 3 and configure the USB settings. Aptio Setup Utility – Copyright (C) 2011 American Megatrends, Inc. Advanced USB Configuration Enable / Disable USB Function. USB Devices: 1 Keyboard USB Function USB 2.
ICE-PV-N4551_D5251 COM Express Type 2 Module Disabled Enabled USB 2.0 (EHCI) support disabled DEFAULT USB 2.0 (EHCI) support enabled Legacy USB Support [Enabled] Use the Legacy USB Support BIOS option to enable USB mouse and USB keyboard support. Normally if this option is not enabled, any attached USB mouse or USB keyboard does not become available until a USB compatible operating system is fully booted with all USB drivers loaded.
ICE-PV-N4551_D5251 COM Express Type 2 Module Aptio Setup Utility – Copyright (C) 2011 American Megatrends, Inc. Advanced PC Health Status Select temperature source CPU Temperature System Temperature FAN 3 Speed Vcc3 VCORE 3.3V VBAT Temperature Source :+89 C :+64 C :N/A :+3.312 :+1.168 :+3.312 :+3.400 [Manual V V V V Fan] --------------------: Select Screen : Select Item Enter Select +/-: Change Opt. F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESC: Exit Version 2.11.
ICE-PV-N4551_D5251 COM Express Type 2 Module 5.3.6 Secondary Super IO Configuration The Secondary Super IO Configuration menu (BIOS Menu 8) displays IO chip type and the submenus for configuring the COM ports 4-6. Aptio Setup Utility – Copyright (C) 2011 American Megatrends, Inc.
ICE-PV-N4551_D5251 COM Express Type 2 Module IO=2C0h; Serial Port I/O port address is 2C0h and the interrupt IRQ=10 address is IRQ10 IO=2C0h; Serial Port I/O port address is 2C0h and the interrupt IRQ=10, 11 address is IRQ10, 11 IO=2C8h; Serial Port I/O port address is 2C8h and the interrupt IRQ=10, 11 address is IRQ10, 11 IO=2D0h; Serial Port I/O port address is 2D0h and the interrupt IRQ=10, 11 address is IRQ10, 11 IO=2D8h; Serial Port I/O port address is 2D8h and the interrupt
ICE-PV-N4551_D5251 COM Express Type 2 Module IO=2D0h; Serial Port I/O port address is 2D0h and the interrupt IRQ=10, 11 address is IRQ10, 11 IO=2D8h; Serial Port I/O port address is 2D8h and the interrupt IRQ=10, 11 address is IRQ10, 11 5.3.6.3 COM 5 Configuration Serial Port [Enabled] Use the Serial Port option to enable or disable the serial port.
ICE-PV-N4551_D5251 COM Express Type 2 Module 5.3.6.4 COM 6 Configuration Serial Port [Enabled] Use the Serial Port option to enable or disable the serial port. Disabled Enabled Disable the serial port DEFAULT Enable the serial port Change Settings [Auto] Use the Change Settings option to change the serial port IO port address and interrupt address. Auto DEFAULT The serial port IO port address and interrupt address are automatically detected.
ICE-PV-N4551_D5251 COM Express Type 2 Module 5.3.7 Super IO Configuration Use the Super IO Configuration menu (BIOS Menu 9) contains the submenus for 3 changing the FDD controllers, parallel ports and serial ports. Aptio Setup Utility – Copyright (C) 2011 American Megatrends, Inc.
ICE-PV-N4551_D5251 COM Express Type 2 Module Device Mode [Read Write] Use the Device Mode option to set the floppy disk controller mode. Read Write Write DEFAULT Sets device mode to Read/Write. Sets the device mode to Write/Protect. Protect 5.3.7.2 COM 1 Configuration Serial Port [Enabled] Use the Serial Port option to enable or disable the serial port.
ICE-PV-N4551_D5251 COM Express Type 2 Module Serial Port I/O port address is 3E8h and the interrupt IO=3E8h; IRQ=3, address is IRQ3, 4, 5, 6, 7, 10, 11, 12 4, 5, 6, 7, 10, 11, 12 Serial Port I/O port address is 2E8h and the interrupt IO=2E8h; IRQ=3, address is IRQ3, 4, 5, 6, 7, 10, 11, 12 4, 5, 6, 7, 10, 11, 12 5.3.7.3 COM 2 Configuration Serial Port [Enabled] Use the Serial Port option to enable or disable the serial port.
ICE-PV-N4551_D5251 COM Express Type 2 Module Serial Port I/O port address is 3F8h and the interrupt IO=3F8h; IRQ=3, address is IRQ3, 4, 5, 6, 7, 10, 11, 12 4, 5, 6, 7, 10, 11, 12 Serial Port I/O port address is 2F8h and the interrupt IO=2F8h; IRQ=3, address is IRQ3, 4, 5, 6, 7, 10, 11, 12 4, 5, 6, 7, 10, 11, 12 Serial Port I/O port address is 3E8h and the interrupt IO=3E8h; IRQ=3, address is IRQ3, 4, 5, 6, 7, 10, 11, 12 4, 5, 6, 7, 10, 11, 12 Serial Port I/O port address is 2E8h a
ICE-PV-N4551_D5251 COM Express Type 2 Module IO=378h; Serial Port I/O port address is 378h and the interrupt IRQ=5 address is IRQ5 IO=378h; Serial Port I/O port address is 378h and the interrupt IRQ=5, 6, address is IRQ5, 6, 7, 10, 11, 12 7, 10, 11, 12 Serial Port I/O port address is 278h and the interrupt IO=278h; IRQ=5, 6, address is IRQ5, 6, 7, 10, 11, 12 7, 10, 11, 12 IO=3BCh; Serial Port I/O port address is 3BCh and the interrupt IRQ=5, address is IRQ5, 6, 7, 10, 11, 12 6,
ICE-PV-N4551_D5251 COM Express Type 2 Module Aptio Setup Utility – Copyright (C) 2011 American Megatrends, Inc. Advanced WinBond W83627EHG HardWare Monitor CPU Fan Speed Fan 2 Speed +12V AVCC 3VCC +3.3V VSB VBAT :N/A :N/A :+10.824 V :+0.160 V :+0.160 V :+3.200 V :+0.144 V :+0.144 V Set Fan at fixed Duty-Cycle Min=0 Max=255 Please input Dec number: --------------------: Select Screen Set Fan Duty Cycle : Select Item CPU Fan Setting 255 Enter Select Fan 2 Setting 255 +/-: Change Opt.
ICE-PV-N4551_D5251 COM Express Type 2 Module 5.3.9 Serial Port Console Redirection The Serial Port Console Redirection menu (BIOS Menu 11) allows the console 3 redirection options to be configured. Console redirection allows users to maintain a system remotely by re-directing keyboard input and text output through the serial port. Aptio Setup Utility – Copyright (C) 2011 American Megatrends, Inc.
ICE-PV-N4551_D5251 COM Express Type 2 Module VT100 The target terminal type is VT100 VT100+ The target terminal type is VT100+ VT-UTF8 The target terminal type is VT-UTF8 ANSI DEFAULT The target terminal type is ANSI Bits per second [115200] Use the Bits per second option to specify the bits per second. 9600 19200 38400 57600 115200 DEFAULT 5.
ICE-PV-N4551_D5251 COM Express Type 2 Module Aptio Setup Utility – Copyright (C) 2011 American Megatrends, Inc. Main Advanced Chipset Boot Security Save & Exit > Host Bridge > South Bridge > Intel IGD SWSCI OpRegion Host Bridge Parameters --------------------: Select Screen : Select Item Enter Select +/-: Change Opt. F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESC: Exit Version 2.11.1210. Copyright (C) 2011 American Megatrends, Inc. BIOS Menu 12: Chipset 5.4.
ICE-PV-N4551_D5251 COM Express Type 2 Module Share Memory Size [8 MB] Use the Share Memory Size option to set the amount of system memory allocated to the integrated graphics processor when the system boots. The system memory allocated can then only be used as graphics memory, and is no longer available to applications or the operating system.
ICE-PV-N4551_D5251 COM Express Type 2 Module 5.4.2 South Bridge Configuration Use the South Bridge Configuration menu (BIOS Menu 14) to configure the 3 Southbridge chipset. Aptio Setup Utility – Copyright (C) 2011 American Megatrends, Inc. Chipset Restore AC Power Loss HD Audio Controller Set Spread Spectrum function [Last State] [Enabled] [Disabled] Select AC power state when power is re-applied after a power failure. --------------------: Select Screen : Select Item Enter Select +/-: Change Opt.
ICE-PV-N4551_D5251 COM Express Type 2 Module Enabled DEFAULT The onboard High Definition Audio controller automatically detected and enabled Set Spread Spectrum Function [Disabled] The Set Spread Spectrum Function option can help to improve CPU EMI issues. Disabled DEFAULT Enabled The spread spectrum mode is disabled The spread spectrum mode is enabled 5.4.
ICE-PV-N4551_D5251 COM Express Type 2 Module DVMT Mode DEFAULT Graphics memory is dynamically allocated according to the system and graphics needs. DVMT/FIXED Memory [Maximum] Use the DVMT/FIXED Memory option to specify the maximum amount of memory that can be allocated as graphics memory. Configuration options are listed below. 128 MB 256 MB Maximum Default IGD - Boot Type [CRT] Use the IGD - Boot Type option to select the display device used by the system when it boots.
ICE-PV-N4551_D5251 COM Express Type 2 Module 5.5 Boot Use the Boot menu (BIOS Menu 16) to configure system boot options. 3 Aptio Setup Utility – Copyright (C) 2011 American Megatrends, Inc. Main Advanced Chipset Boot Security Save & Exit Boot Configuration Boot NumLock State [On] Quiet Boot Launch PXE OpROM [Disabled] [Disabled] Select the keyboard NumLock state --------------------: Select Screen Boot Option Priorities : Select Item Enter Select +/-: Change Opt.
ICE-PV-N4551_D5251 COM Express Type 2 Module Quiet Boot [Disabled] Use the Quiet Boot BIOS option to select the screen display when the system boots. Disabled Enabled DEFAULT Normal POST messages displayed OEM Logo displayed instead of POST messages Launch PXE OpROM [Disabled] Use the Launch PXE OpROM option to enable or disable boot option for legacy network devices. Disabled Enabled DEFAULT Ignore all PXE Option ROMs Load PXE Option ROMs 5.
ICE-PV-N4551_D5251 COM Express Type 2 Module Administrator Password Use the Administrator Password to set or change an administrator password. User Password Use the User Password to set or change a user password. Set User Password Use the Set User Password to set or change an HDD user password. NOTE: After an HDD password is set or changed, it is recommended that user restart the system. 5.
ICE-PV-N4551_D5251 COM Express Type 2 Module Save Changes and Reset Use the Save Changes and Reset option to save the changes made to the BIOS options and to exit the BIOS configuration setup program. Discard Changes and Reset Use the Discard Changes and Reset option to exit the system without saving the changes made to the BIOS configuration setup program. Restore Defaults Use the Restore Defaults option to load the optimal default values for each of the parameters on the Setup menus.
ICE-PV-N4551_D5251 COM Express Type 2 Module Chapter 6 6 Software Installation Page 70
ICE-PV-N4551_D5251 COM Express Type 2 Module 6.1 Available Software Drivers NOTE: The content of the CD may vary throughout the life cycle of the product and is subject to change without prior notice. Visit the IEI website or contact technical support for the latest updates. The following drivers can be installed on the system: Chipset Graphic LAN Audio SATA iSMM Manual TPM ION Installation instructions are given below. 6.
ICE-PV-N4551_D5251 COM Express Type 2 Module Step 2: The screen in Figure 6-1 appears. Figure 6-1: Start Up Screen Step 3: Click ICE-PV-N4551/D5251. Step 4: The list of drivers in Figure 6-2 appears.
ICE-PV-N4551_D5251 COM Express Type 2 Module Figure 6-2: Drivers Step 5: Install the necessary drivers from the list.
ICE-PV-N4551_D5251 COM Express Type 2 Module Appendix A A BIOS Options Page 74
ICE-PV-N4551_D5251 COM Express Type 2 Module Below is a list of BIOS configuration options in the BIOS chapter. BIOS Information .................................................................................................................40 System Date [xx/xx/xx] ........................................................................................................41 System Time [xx:xx:xx] .......................................................................................................
ICE-PV-N4551_D5251 COM Express Type 2 Module Device Mode [Printer Mode]................................................................................................57 CPU Fan Setting...................................................................................................................58 Fan 2 Setting ........................................................................................................................58 Console Redirection [Enabled]...........................................
ICE-PV-N4551_D5251 COM Express Type 2 Module Appendix B B Terminology Page 77
ICE-PV-N4551_D5251 COM Express Type 2 Module AC ’97 Audio Codec 97 (AC’97) refers to a codec standard developed by Intel® in 1997. ACPI Advanced Configuration and Power Interface (ACPI) is an OS-directed configuration, power management, and thermal management interface. AHCI Advanced Host Controller Interface (AHCI) is a SATA Host controller register-level interface. ATA The Advanced Technology Attachment (ATA) interface connects storage devices including hard disks and CD-ROM drives to a computer.
ICE-PV-N4551_D5251 COM Express Type 2 Module DMA Direct Memory Access (DMA) enables some peripheral devices to bypass the system processor and communicate directly with the system memory. DIMM Dual Inline Memory Modules are a type of RAM that offer a 64-bit data bus and have separate electrical contacts on each side of the module. DIO The digital inputs and digital outputs are general control signals that control the on/off circuit of external devices or TTL devices.
ICE-PV-N4551_D5251 COM Express Type 2 Module LCD Liquid crystal display (LCD) is a flat, low-power display device that consists of two polarizing plates with a liquid crystal panel in between. LVDS Low-voltage differential signaling (LVDS) is a dual-wire, high-speed differential electrical signaling system commonly used to connect LCD displays to a computer. POST The Power-on Self Test (POST) is the pre-boot actions the system performs when the system is turned-on.
ICE-PV-N4551_D5251 COM Express Type 2 Module Appendix C C Watchdog Timer Page 81
ICE-PV-N4551_D5251 COM Express Type 2 Module NOTE: The following discussion applies to DOS environment. IEI support is contacted or the IEI website visited for specific drivers for more sophisticated operating systems, e.g., Windows and Linux. The Watchdog Timer is provided to ensure that standalone systems can always recover from catastrophic conditions that cause the CPU to crash. This condition may have occurred by external EMIs or a software bug.
ICE-PV-N4551_D5251 COM Express Type 2 Module NOTE: When exiting a program it is necessary to disable the Watchdog Timer, otherwise the system resets.
ICE-PV-N4551_D5251 COM Express Type 2 Module Appendix D D Hazardous Materials Disclosure Page 84
ICE-PV-N4551_D5251 COM Express Type 2 Module D.1 Hazardous Materials Disclosure Table for IPB Products Certified as RoHS Compliant Under 2002/95/EC Without Mercury The details provided in this appendix are to ensure that the product is compliant with the Peoples Republic of China (China) RoHS standards. The table below acknowledges the presences of small quantities of certain materials in the product, and is applicable to China RoHS only.
ICE-PV-N4551_D5251 COM Express Type 2 Module Part Name Toxic or Hazardous Substances and Elements Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated (Pb) (Hg) (Cd) Chromium Biphenyls Diphenyl (CR(VI)) (PBB) Ethers (PBDE) Housing X O O O O X Display X O O O O X Printed Circuit X O O O O X X O O O O O X O O O O X Fan Assembly X O O O O X Power Supply X O O O O X O O O O O O Board Metal Fasteners Cable Assembly Assemblies Battery
ICE-PV-N4551_D5251 COM Express Type 2 Module 此附件旨在确保本产品符合中国 RoHS 标准。以下表格标示此产品中某有毒物质的含量符 合中国 RoHS 标准规定的限量要求。 本产品上会附有”环境友好使用期限”的标签,此期限是估算这些物质”不会有泄漏或突变”的 年限。本产品可能包含有较短的环境友好使用期限的可替换元件,像是电池或灯管,这些元 件将会单独标示出来。 部件名称 有毒有害物质或元素 铅 汞 镉 六价铬 多溴联苯 多溴二苯 (Pb) (Hg) (Cd) (CR(VI)) (PBB) 醚 (PBDE) 壳体 X O O O O X 显示 X O O O O X 印刷电路板 X O O O O X 金属螺帽 X O O O O O 电缆组装 X O O O O X 风扇组装 X O O O O X 电力供应组装 X O O O O X 电池 O O O O O O O: 表示该有毒有害物质在该部件所有物质材料中的含量均在 SJ/