Safety Information

www.tuv.com
Page 10 of 59
Report No.: 50261218 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1G
1.7.2.1
General
P
1.7.2.2
Disconnect devices
Mains plug serves as
disconnect device.
P
1.7.2.3
Overcurrent protective device
Not such equipment.
N/A
1.7.2.4
IT power distribution systems
N/A
1.7.2.5
Operator access with a tool
No operator accessible area
that needs to be accessed by
the use of a tool.
N/A
1.7.2.6
Ozone
Not such equipment.
N/A
1.7.3
Short duty cycles
Equipment is designed for
continuous operation.
N/A
1.7.4
Supply voltage adjustment .............................. :
No voltage selector.
N/A
Methods and means of adjustment; reference to
installation instructions ................................... :
N/A
1.7.5
Power outlets on the equipment ....................... :
No power outlets provided.
N/A
1.7.6
Fuse identification (marking, special fusing
characteristics, cross
-reference)
...................... :
ā€œF1 T5AL 250Vā€ marked near
current fuse F1
P
1.7.7
Wiring terminals
See below.
N/A
1.7.7.1
Protective earthing and bonding terminals ......... :
Class II equipment.
N/A
1.7.7.2
Terminals for a.c. mains supply conductors
No such terminals.
N/A
1.7.7.3
Terminals for d.c. mains supply conductors
No such terminals.
N/A
1.7.8
Controls and indicators
No controls and indicators
affect to safety provided
N/A
1.7.8.1
Identification, location and marking ................... :
No switches and controls.
N/A
1.7.8.2
Colours ....................................................... :
N/A
1.7.8.3
Symbols according to IEC 60417 ..................... :
No symbols used.
N/A
1.7.8.4
Markings using figures .................................. :
No indicators for different
positions.
N/A
1.7.9
Isolation of multiple power sources .................. :
Single power source
N/A
1.7.10
Thermostats and other regulating devices ........ :
Such devices not used.
N/A