Safety Information

www.tuv.com
Page 11 of 59
Report No.: 50261218 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1G
1.7.11
Durability
The label was subjected to the
permanence of marking test.
The label was rubbed with
cloth soaked with water for 15
sec. And then again for 15
sec. With the cloth soaked
with petroleum spirit.
After this test there was no
damage to the label. The
marking on the label did not
fade. There was no curling
and lifting of the label edge.
P
1.7.12
Removable parts
No removable part.
N/A
1.7.13
Replaceable batteries .................................... :
No battery provided.
N/A
Language(s) ................................................ :
¾
1.7.14
Equipment for restricted access locations.......... :
Not intended for use in
restricted access locations.
N/A
2
PROTECTION FROM HAZARDS
P
2.1
Protection from electric shock and energy hazards
P
2.1.1
Protection in operator access areas
No access with test finger and
test pin to any hazardous parts.
P
2.1.1.1
Access to energized parts
See above.
P
Test by inspection ........................................... :
See above.
P
Test with test finger (Figure 2A) ........................ :
See above.
P
Test with test pin (Figure 2B) ............................ :
See above.
P
Test with test probe (Figure 2C) ........................ :
No TNV.
N/A
2.1.1.2
Battery compartments
No battery compartment.
N/A
2.1.1.3
Access to ELV wiring
No ELV wiring in operator
accessible area.
N/A
Working voltage (Vpeak or Vrms); minimum
distance through insulation (mm)
(see appended table 2.10.5)
¾
2.1.1.4
Access to hazardous voltage circuit wiring
No hazardous voltage wiring in
operator accessible area.
N/A
2.1.1.5
Energy hazards .............................................. :
The energy does not exceed
240VA between any two points
in accessible connector of
secondary circ
uit.
(see appended table 2.1.1.5
c)1))
P
2.1.1.6
Manual controls
No manual controls.
N/A