Safety Information

www.tuv.com
Page 12 of 59
Report No.: 50261218 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1G
2.1.1.7
Discharge of capacitors in equipment
P
Measured voltage (V); time-constant (s).............. :
Vpeak=366V, 37% of
Vpeak=136V, time
-
constant:
0.11s
¾
2.1.1.8
Energy hazards d.c. mains supply
Connected to a.c. mains.
N/A
a) Capacitor connected to the d.c. mains supply .. :
N/A
b) Internal battery connected to the d.c. mains
supply ........................................................... :
N/A
2.1.1.9
Audio amplifiers .............................................. :
Not such equipment.
N/A
2.1.2
Protection in service access areas
No operator accessible area
that needs to be accessed by
the use of a tool.
N/A
2.1.3
Protection in restricted access locations
Not intended for use in
restricted access locations.
N/A
2.2
SELV circuits
P
2.2.1
General requirements
The secondary circuits were
tested as SELV. See 2.2.2 to
2.2.4.
P
2.2.2
Voltages under normal conditions (V) ................:
Between any conductors of
the SELV circuits 42.4 V peak
or 60 V d.c. are not exceeded.
See appended table 2.2.
P
2.2.3
Voltages under fault conditions (V) ....................:
Single fault did not cause
excessive voltage in
accessible SELV circuits.
Limits of 71V peak and 120V
peak were not exceeded
within 0.2 seconds and limits
42.4V peak and 60V d.c. were
not exceeded for longer than
0.2 seconds.
P
2.2.4
Connection of SELV circuits to other circuits ..... :
See sub-clauses 2.2.2 and
2.2.3. and 2.4.2
P
2.3
TNV circuits No TNV circuits used
N/A
2.3.1
Limits
N/A
Type of TNV circuits ........................................:
¾
2.3.2
Separation from other circuits and from accessible
parts
N/A
2.3.2.1
General requirements
N/A
2.3.2.2
Protection by basic insulation
N/A
2.3.2.3
Protection by earthing
N/A