Safety Information

www.tuv.com
Page 15 of 59
Report No.: 50261218 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1G
2.7.1
Basic requirements
The equipment relies on fuse
or circuit breaker of the wall
outlet protection of the building
installation in regard
to L to N
short
-circuits and earth
fault
condition. A build
-in fuse
provided as overcurrent
protection device (see 5.3)
P
Instructions when protection relies on building
installation
Pluggable equipment type A.
N/A
2.7.2
Faults not simulated in 5.3.7
The protection devices are well
dimensioned and mounted.
P
2.7.3
Short-circuit backup protection
Building installation is
considered as providing short-
circuit backup protection.
P
2.7.4
Number and location of protective devices ..........:
Overcurrent protection by one
built-in current fuse.
P
2.7.5
Protection by several devices
Protection provided by one
fuse only.
N/A
2.7.6
Warning to service personnel ............................:
No service work necessary.
N/A
2.8
Safety interlocks No safety interlocks used
N/A
2.8.1
General principles
N/A
2.8.2
Protection requirements
N/A
2.8.3
Inadvertent reactivation
N/A
2.8.4
Fail-safe operation
N/A
Protection against extreme hazard
N/A
2.8.5
Moving parts
N/A
2.8.6
Overriding
N/A
2.8.7
Switches, relays and their related circuits
N/A
2.8.7.1
Separation distances for contact gaps and their
related circuits (mm) ....................................... :
N/A
2.8.7.2
Overload test
N/A
2.8.7.3
Endurance test
N/A
2.8.7.4
Electric strength test
N/A
2.8.8
Mechanical actuators
N/A
2.9
Electrical insulation
P
2.9.1
Properties of insulating materials
Natural rubber, asbestos or
hygroscopic material not used.
P