Safety Information

www.tuv.com
Page 19 of 59
Report No.: 50261218 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1G
2.10.8.2
Thermal conditioning
N/A
2.10.8.3
Electric strength test
N/A
2.10.8.4
Abrasion resistance test
N/A
2.10.9
Thermal cycling
N/A
2.10.10
Test for Pollution Degree 1 environment and
insulating compound
N/A
2.10.11
Tests for semiconductor devices and cemented
joints
No such devices except
approved optocoupler.
N/A
2.10.12
Enclosed and sealed parts
No hermetically sealed
component except optocoupler.
N/A
3
WIRING, CONNECTIONS AND SUPPLY
P
3.1
General
P
3.1.1
Current rating and overcurrent protection
Internal wiring gauge is
suitable for current intended to
be carried.
P
3.1.2
Protection against mechanical damage
The internal wires do not touch
sharp edges which could
damage the insulation
&
cause
hazard.
P
3.1.3
Securing of internal wiring
The internal wires are secured
by
soldering and glue
on PCB,
so t
hat a loosening of the
terminal connection is unlikely.
P
3.1.4
Insulation of conductors
The insulation of the individual
conductors suitable for the
application and the working
voltage.
P
3.1.5
Beads and ceramic insulators
Not used.
N/A
3.1.6
Screws for electrical contact pressure
No such screws provided.
N/A
3.1.7
Insulating materials in electrical connections
For enclosure in contact with
plug pin contacts
contact
pressure is not transmitted
through insulating material.
P
3.1.8
Self-tapping and spaced thread screws
Not used.
N/A
3.1.9
Termination of conductors
All conductors are reliable
secured. See also 3.1.3.
P
10 N pull test
Force of 10 N applied to the
termination points of the
conductors.
P
3.1.10
Sleeving on wiring
N/A