Report No.: 50261218 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1G
3.2
Connection to a mains supply
P
3.2.1
Means of connection
See below.
P
3.2.1.1
Connection to an a.c. mains supply
The adaptor provided with a
mains plug.
P
3.2.1.2
Connection to a d.c. mains supply
Only a.c. mains supply.
N/A
3.2.2
Multiple supply connections
Only for one mains connection.
N/A
3.2.3
Permanently connected equipment
Unit is not a permanently
connected equipment.
N/A
Number of conductors, diameter of cable and
conduits (mm) ................................................:
¾
3.2.4
Appliance inlets
No such component used.
N/A
3.2.5
Power supply cords
N/A
3.2.5.1
AC power supply cords
N/A
Type .............................................................:
¾
Rated current (A), cross-sectional area (mm
2
),
AWG ............................................................:
¾
3.2.5.2
DC power supply cords
AC Source.
N/A
3.2.6
Cord anchorages and strain relief
N/A
Mass of equipment (kg), pull (N) ......................:
¾
Longitudinal displacement (mm) .......................:
¾
3.2.7
Protection against mechanical damage
N/A
3.2.8
Cord guards
N/A
Diameter or minor dimension D (mm); test mass (g)
.....................................................................:
¾
Radius of curvature of cord (mm) .......................:
¾
3.2.9
Supply wiring space
Not permanent connection or
non
-
detachable power cord
type.
N/A
3.3
Wiring terminals for connection of external conductors
N/A
3.3.1
Wiring terminals
N/A
3.3.2
Connection of non-detachable power supply cords
N/A
3.3.3
Screw terminals
N/A
3.3.4
Conductor sizes to be connected
N/A
Rated current (A), cord/cable type, cross-sectional
area (mm
2
) .....................................................:
¾
3.3.5
Wiring terminal sizes
N/A