Safety Information
www.tuv.com
Page 22 of 59
Report No.: 50261218 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1G
4.2
Mechanical strength
P
4.2.1
General
See below. After tests, unit
complies with the
requirements of sub
-
clauses
2.1.1 and 2.10.
P
Rack-mounted equipment.
N/A
4.2.2
Steady force test, 10 N
10 N applied to all internal
components.
P
4.2.3
Steady force test, 30 N
No internal enclosure.
N/A
4.2.4
Steady force test, 250 N
250 N applied to outer
enclosure. No energy or other
hazards.
P
4.2.5
Impact test
N/A
Fall test
N/A
Swing test
N/A
4.2.6
Drop test; height (mm) ..................................... :
The power supply has been
subjected to 3 drops from 1 m
height on a hard wooden
surface.
P
4.2.7
Stress relief test
After the test at temperature of
105
°
C, no shrinkage, distortion
or loosening of any enclosure
part was noticeable on the
equipment
.
P
4.2.8
Cathode ray tubes
No CRT in the unit.
N/A
Picture tube separately certified ........................ :
N/A
4.2.9
High pressure lamps
No high pressure lamp
provided.
N/A
4.2.10
Wall or ceiling mounted equipment; force (N) ...... :
Not wall or ceiling mounted
equipment.
N/A
4.3
Design and construction
P
4.3.1
Edges and corners
Edges and corners of the
enclosure are rounded.
P
4.3.2
Handles and manual controls; force (N) ........... :
No handles or controls
provided.
N/A
4.3.3
Adjustable controls
No such controls provided.
N/A