Safety Information

www.tuv.com
Page 24 of 59
Report No.: 50261218 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1G
4.3.13.4
Human exposure to ultraviolet (UV) radiation ..... :
N/A
4.3.13.5
Lasers (including laser diodes) and LEDs
The LED is considered as
indicating light.
P
4.3.13.5.1
Lasers (including laser diodes)
N/A
Laser class ................................................... :
¾
4.3.13.5.2
Light emitting diodes (LEDs)
Indicating LED on secondary
is inherently exempted group
according to IEC 62471.
¾
4.3.13.6
Other types ................................................... :
N/A
4.4
Protection against hazardous moving parts No moving parts
N/A
4.4.1
General
N/A
4.4.2
Protection in operator access areas .................. :
N/A
Household and home/office document/media
shredders
N/A
4.4.3
Protection in restricted access locations ............ :
N/A
4.4.4
Protection in service access areas
N/A
4.4.5
Protection against moving fan blades
N/A
4.4.5.1
General
N/A
Not considered to cause pain or injury. A)……….:
N/A
Is considered to cause pain, not injury. B) ……:
N/A
Considered to cause injury. C) ……:
N/A
4.4.5.2
Protection for users
N/A
Use of symbol or warning …………………………:
N/A
4.4.5.3
Protection for service persons
N/A
Use of symbol or warning …………………………:
N/A
4.5
Thermal requirements
P
4.5.1
General
Equipment loaded with rated
output current.
P
4.5.2
Temperature tests
(see appended table 4.5)
P
Normal load condition per Annex L ................... :
(see appended table 1.6.2)
¾
4.5.3
Temperature limits for materials
(see appended table 4.5)
P
4.5.4
Touch temperature limits
(see appended table 4.5)
P
4.5.5
Resistance to abnormal heat ........................... :
Phenolic bobbin material used
in
transformer T1 and line
choke LF2
which is
acceptable
without test. For other parts,
see appended table 4.5.5.
P