Report No.: 50261218 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1G
4.6
Openings in enclosures
P
4.6.1
Top and side openings
No openings except opening
of
AC plug
which is covered by
AC plug
and plug
holder of top
enclosure. Remaining opening
<1mm.
P
Dimensions (mm) .......................................... :
¾
4.6.2
Bottoms of fire enclosures
No openings except one USB
output.
P
Construction of the bottom, dimensions (mm) .... :
¾
4.6.3
Doors or covers in fire enclosures
N/A
4.6.4
Openings in transportable equipment
N/A
4.6.4.1
Constructional design measures
N/A
Dimensions (mm) .......................................... :
¾
4.6.4.2
Evaluation measures for larger openings
N/A
4.6.4.3
Use of metallized parts
N/A
4.6.5
Adhesives for constructional purposes
N/A
Conditioning temperature (
°
C), time (weeks)....... :
¾
4.7
Resistance to fire
P
4.7.1
Reducing the risk of ignition and spread of flame
No excessive temperatures.
No easily burning materials
employed. Fi
re enclosure
provided.
P
Method 1, selection and application of components
wiring and materials
(see appended table 4.7)
P
Method 2, application of all of simulated fault
condition tests
N/A
4.7.2
Conditions for a fire enclosure
See below.
P
4.7.2.1
Parts requiring a fire enclosure
With having the following parts
Components in primary
Components having
unenclosed arcing parts at
hazardous voltage or energy
level
Insulated wiring
The fire enclosure is required.
P
4.7.2.2
Parts not requiring a fire enclosure
N/A
4.7.3
Materials
P
4.7.3.1
General
See below
P