Report No.: 50261218 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1G
4.7.3.2
Materials for fire enclosures
V-0 fire enclosure used.
P
4.7.3.3
Materials for components and other parts outside
fire enclosures
N/A
4.7.3.4
Materials for components and other parts inside
fire enclosures
PCB rated V-1. See appended
table 1.
5.1.
Internal components except
small parts are V-2 or better.
P
4.7.3.5
Materials for air filter assemblies
No air filters provided.
N/A
4.7.3.6
Materials used in high-voltage components
No high voltage components
provided.
N/A
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
P
5.1
Touch current and protective conductor current
P
5.1.1
General
See sub-clauses 5.1.2 to
5.1.6.
P
5.1.2
Configuration of equipment under test (EUT)
EUT has only one mains
connection.
P
5.1.2.1
Single connection to an a.c. mains supply
P
5.1.2.2
Redundant multiple connections to an a.c. mains
supply
N/A
5.1.2.3
Simultaneous multiple connections to an a.c.
mains supply
N/A
5.1.3
Test circuit
Equipment of figure 5A used.
P
5.1.4
Application of measuring instrument
Using measuring instrument in
annex D.
P
5.1.5
Test procedure
The touch current was
measured from mains to DC
output connector and to a 100
mm
´ 200 mm metal foil
wrapped on accessible non-
conductive parts (plastic
enclosure).
P
5.1.6
Test measurements
(see appended table 5.1)
P
Supply voltage (V) ......................................... :
¾
Measured touch current (mA) .......................... :
¾
Max. Allowed touch current (mA) ..................... :
¾
Measured protective conductor current (mA) ...... :
¾
Max. Allowed protective conductor current (mA) .. :
¾
5.1.7
Equipment with touch current exceeding 3,5 mA
Touch current does not exceed
3.5mA.
N/A