Safety Information

www.tuv.com
Page 27 of 59
Report No.: 50261218 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1G
5.1.7.1
General ........................................................ :
N/A
5.1.7.2
Simultaneous multiple connections to the supply
N/A
5.1.8
Touch currents to telecommunication networks and
cable distribution systems and fr
om
telecommunication networks
No TNV.
N/A
5.1.8.1
Limitation of the touch current to a
telecommunication network or to a cable
distribution system
N/A
Supply voltage (V) ......................................... :
¾
Measured touch current (mA) .......................... :
¾
Max. Allowed touch current (mA) ..................... :
¾
5.1.8.2
Summation of touch currents from
telecommunication networks
N/A
a) EUT with earthed telecommunication ports .... :
N/A
b) EUT whose telecommunication ports have no
reference to protective earth
N/A
5.2
Electric strength
P
5.2.1
General
(see appended table 5.2)
P
5.2.2
Test procedure
(see appended table 5.2)
P
5.3
Abnormal operating and fault conditions
P
5.3.1
Protection against overload and abnormal
operation
(see appended table 5.3)
P
5.3.2
Motors
No motors.
N/A
5.3.3
Transformers
(see appended Annex C and
table 5.3)
P
5.3.4
Functional insulation ....................................... :
By short-circuited, results see
appended table 5.3.
P
5.3.5
Electromechanical components
No electromechanical
component .
N/A
5.3.6
Audio amplifiers in ITE ................................... :
Audio amplifiers not used.
N/A
5.3.7
Simulation of faults
(see appended table 5.3.)
P
5.3.8
Unattended equipment
No such equipment.
N/A
5.3.9
Compliance criteria for abnormal operating and
fault conditions
P
5.3.9.1
During the tests
No fire or molten metal
occurred and no deformation of
enclosure during the tests.
P