Report No.: 50261218 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1G
NEW MATERIALS
TECHNOLOGY
CO LTD
C22.2 No. 0
Supplementary information:
1)
Provided evidence ensures the agreed level of compliance.
1.6.2
TABLE: Electrical data (in normal conditions)
P
U (V/Hz)
I (A)
Irated (A)
P (W)
Fuse #
Ifuse (A)
Condition/status
90V/50Hz
--
0.403
18.0
F1
0.403
Loaded with 5Vdc, 3A.
100V/50Hz
2
0.360
18.0
F1
0.360
240V/50Hz
2
0.189
18.4
F1
0.189
264V/50Hz
--
0.163
18.7
F1
0.163
90V/60Hz
--
0.392
18.0
F1
0.392
100V/60Hz
2
0.356
18.0
F1
0.356
240V/60Hz
2
0.182
18.6
F1
0.182
264V/60Hz
--
0.168
18.9
F1
0.168
90V/50Hz
--
0.687
30.2
F1
0.687
Loaded with 9Vdc, 3A.
100V/50Hz
2
0.606
30.1
F1
0.606
240V/50Hz
2
0.278
30.6
F1
0.278
264V/50Hz
--
0.253
30.9
F1
0.253
90V/60Hz
--
0.634
30.2
F1
0.634
100V/60Hz
2
0.571
30.2
F1
0.571
240V/60Hz
2
0.283
30.7
F1
0.283
264V/60Hz
--
0.255
30.9
F1
0.255
90V/50Hz
--
0.908
40.2
F1
0.908
Loaded with 12Vdc, 3A.
100V/50Hz
2
0.808
40.0
F1
0.808
240V/50Hz
2
0.354
40.3
F1
0.354
264V/50Hz
--
0.343
40.6
F1
0.343
90V/60Hz
--
0.823
40.1
F1
0.823
100V/60Hz
2
0.742
40.2
F1
0.742
240V/60Hz
2
0.361
40.4
F1
0.361
264V/60Hz
--
0.324
40.5
F1
0.324
90V/50Hz
--
1.112
50.2
F1
1.112
Loaded with 15Vdc, 3A.
100V/50Hz
2
1.004
50.0
F1
1.004
240V/50Hz
2
0.436
50.0
F1
0.436
264V/50Hz
--
0.391
50.3
F1
0.391