Safety Information

www.tuv.com
Page 4 of 59
Report No.: 50261218 001
TRF No. IEC60950_1G
List of Attachments (including a total number of pages in each attachment):
-
see cover page
Summary of testing:
Tests performed (name of test and test clause):
1.
Max. ambient temperature +25°C.
2.
Following tests performed during evaluation
Clause(s)
Test(s)
1.6.2
Input Current Test
1.7.11
Durability of Marking Test
2.1.1.1
Access to energized parts
2.1.1.5
Energy Hazard in Operator Access Area
2.1.1.7
Discharge of Capacitors
2.2.2
SELV limits for Normal Conditions
2.2.3
SELV limits for Abnormal Conditions
2.4
Limited current circuits
2.5
Limited Power Sourecs
2.9.2
Humidity Conditioning
2.10.2
Working Voltage over Insulation
2.10.3 &
2.10.4
Clearance and creepage distance
measurements
4.2.4
Steady force test
4.2.6
Drop Test
4.2.7
Stress relief test
4.3.6
Torque Test
4.5.2
Maximum Temperature Test
4.5.5
Ball Pressure Test
5.1.6
Touch Current and PE current
5.2
Electric Strength Test
5.3
Fault Condition Test
All test are conducted on model
MZ90PD-1 to repres
ents other
model.
The EUTs passed the test.
Testing location:
See cover page
Summary of compliance with National Differences
CA = Canada, US = United States of America
For national difference, s
ee end of this test report.