Safety Information

www.tuv.com
Page 40 of 59
Report No.: 50261218 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1G
90V/60Hz
--
1.011
50.2
F1
1.011
100V/60Hz
2
0.920
50.1
F1
0.920
240V/60Hz
2
0.439
50.1
F1
0.439
264V/60Hz
--
0.396
50.4
F1
0.396
90V/50Hz
--
2.013
103.6
F1
2.013
Loaded with 20Vdc, 4.5A.
100V/50Hz
2
1.956
102.8
F1
1.956
240V/50Hz
2
0.928
100.8
F1
0.928
264V/50Hz
--
0.755
101.1
F1
0.755
90V/60Hz
--
2.043
103.5
F1
2.043
100V/60Hz
2
1.801
102.6
F1
1.801
240V/60Hz
2
0.862
100.8
F1
0.862
264V/60Hz
--
0.761
101.0
F1
0.761
Supplementary information: measured current at rated voltage did not exceed Irated by +10%.
2.1.1.5 c) 1)
TABLE: max. V, A, VA test
P
Voltage (rated)
(V)
Current (rated)
(A)
Voltage (max.)
(V)
Current (max.)
(A)
VA (max.)
(VA)
20
4.5
20.2
4.66
92.98
supplementary information:--
2.2
TABLE: evaluation of voltage limiting components in SELV circuits
P
Component (measured between)
max. voltage (V)
(normal operation)
Voltage Limiting Components
V peak
V d.c.
T1 pin 6,7 to 9,10
72
--
--
T1 pin 6,7 to 9,10 (After D7)
--
20.1
D7
Fault test performed on voltage limiting components
Voltage measured (V) in SELV circuits
(V peak or V d.c.)
D7
0 (unit shut down)
Supplied by: 264V/60Hz, loaded with 20Vdc, 4.5A