Safety Information

www.tuv.com
Page 50 of 59
Report No.: 50261218 001
National Differences
Clause
Requirement + Test
Result - Remark
Verdict
Canada National Differences
1.7.7
Wiring terminals intended to supply Class 2 outputs
in accordance with CEC Part 1 or NEC shall be
marked with the voltage rating and “Class 2or
equivalent. Marking shall be located adjacent to
the terminals and shall be visible during wiring.
N/A
2.5
Where a fuse is used to provide Class 2, Limited
Power Source, or TNV current limiting, it shall not
be operator
-accessible unless it is not
interchangeable.
Not used for such kind of
equipment.
N/A
2.6
Equipment with isolated ground (earthing)
receptacles are required to comp
ly with NEC
250.146(D) and CEC 10-112 and 10-906(8).
N/A
2.7.1
Suitable NEC/CEC branch circuit protection rated
at the maximum circuit rating is required for all
standard supply outlets and receptacles (such as
supplied in power distribution units) if the supply
branch circuit protection is not suitable.
Power distribution transformers distributing power
at 100 volts or more, and rated 10 kVA or more,
require special transformer overcurrent protection.
No such parts.
N/A
3.2
Wiring methods (terminals, leads, etc.) used for the
connection of the equipment to the mains shall be
in accordance with the NEC/CEC.
N/A
3.2.1
Power supply cords are required to have
attachment plugs rated not less than 125 percent of
the rated current of the equipment.
N/A
3.2.1.2
Equipment connected to a centralized d.c. power
system, and having one pole of the DC mains input
terminal connected to the main protective earthing
terminal in the equipment, is required to comply
with special earthing, wiring, marking and
installation instruction requirements.
No connection to a centralized
d.c. power system
.
N/A
3.2.3
Permanent connection of equipment to the mains
supply by a power supply cord is not permitted,
except for certain equipment, such as ATMs.
N/A
3.2.5
Power supply cords are required to be no longer
than 4.5 m in length.
Minimum cord length is required to be 1.5 m, with
certain constructions such as external power
supplies allowed to consider both input and output
cord lengths into the requirement.
Flexible power supply cords are required to be
compatible with Article 400 of the NEC, and Tables
11 and 12 of the CEC.
N/A
3.2.9
Permanently connected equipment is required to
have a suitable wiring compartment and wire
bending space.
Pluggable equipment type A.
N/A
3.3
Wiring terminals and associated spacings for field
wiring connections shall comply with CSA C22.2
No. 0
N/A