Safety Information

www.tuv.com
Page 51 of 59
Report No.: 50261218 001
National Differences
Clause
Requirement + Test
Result - Remark
Verdict
Canada National Differences
3.3.3
Wire binding screws are not permitted to attach
conductors larger than 10 AWG (5.3 mm2).
No wiring terminals.
N/A
3.3.4
Terminals for permanent wiring, including
protective earthing terminals, are required to be
suitable for US/Canadian wire gauge sizes, rated
125 percent of the equipment rating, and be
specially marked when specified (1.7.7).
Pluggable equipment type A.
N/A
3.3.5
First column of Table 3E revised to require
Smaller of the RATED CURRENT of the
equipment or the PROTECTIVE CURRENT
RATING of the circuit under consideration.
N/A
3.4.2
Motor control devices are required for
cord
-connected equipment with a motor if the
equipment
is rated more than 12 A, or if the motor
has a nominal voltage rating greater than 120 V, or
is rated more than 1/3 hp (locked rotor current over
43 A).
Equipment is not such a
device.
N/A
3.4.8
Vertically-mounted disconnect switches and circuit
breakers have the "on" position indicated by the
handle in the up position.
No such switches or breakers.
N/A
3.4.11
For computer room applications, equipment with
battery systems capable of supplying 750 VA for
five minutes are required to have a battery
disconnect means that may be connected to the
computer room remote power-off circuit.
Not such an application.
N/A
4.3.12
The maximum quantity of flammable liquid stored
in equipment is required to comply with NFPA 30.
No liquids provided.
N/A
4.3.13.5.1
Equipment with lasers is required to meet the U.S.
Code of Federal Regulations 21 CFR 1040 (and
the Canadian Radiation Emitting Devices Act,
REDR C1370).
No laser provided.
N/A
4.7
For computer room applications, automated
information storage systems with comb
ustible
media greater than 0.76 m3 (27 cu ft) are required
to have a provision for connection of either
automatic sprinklers or a gaseous agent
extinguishing system with an extended discharge.
Not such an application.
N/A
4.7.3.1
For computer room applications, enclosures with
combustible material measuring greater than 0.9
m2 (10 sq ft) or a single dimension greater than 1.8
m (6 ft) are required to have a flame spread rating
of 50 or less. For other applications, enclosures
with the same dimensions require a flame spread
rating of 200 or less.
Not such an application.
N/A
Non-metallic enclosures of equipment for use in
spaces used for environmental air (plenums) are
required to comply with UL 2043.
Not such an application.
N/A
Annex H
Equipment that produces ionizing radiation is
required to comply with the U.S. Code of Federal
Regulations, 21 CFR 1020 (and the Canadian
Radiation Emitting Devices Act, REDR C1370).
No ionizing radiation.
N/A