Safety Information

www.tuv.com
Page 53 of 59
Report No.: 50261218 001
National Differences
Clause
Requirement + Test
Result - Remark
Verdict
Canada National Differences
4.2.8.1
Enclosures around CRTs with a face diameter of
160 mm or more are required to reduce the risk of
injury due to the implosion of the CRT.
No CRTs.
N/A
4.3.2
Equipment with handles complies with special
loading tests.
No handles.
N/A
4.3.8
Battery packs for both portable and stationary
applications are required to comply with special
component requirements.
N/A
5.1.8.3
Equipment intended to receive telecommunication
ringing signals is required to comply with
a special
touch current measurement tests.
No TNV circuits.
N/A
5.3.7
Internal (e.g., card cage) SELV circuit connectors
and printed wiring board connectors that are
accessible to the operator and that deliver power
are to be overloaded.
During abnormal operating testing, if a circuit is
interrupted by the opening of a component, the test
shall be repeated twice (three tests total) using new
components as necessary.
Considered.
P
6.4
Equipment intended for connection to
telecommunication network outside plant cable is
required to be protected against overvoltage from
power line crosses in accordance with 6.4 and
Annex NAC.
No TNV circuits.
N/A
Annex EE
UL articulated accessibility probe (Fig EE.3)
required for assessing accessibility to
document/media shredders instead of the Figure
2A test finger.
Not such equipment.
N/A
M.2
Continuous ringing signals up to 16 mA only are
permitted if the equipment is subjected to special
installation and performance restrictions.
No TNV circuits.
N/A
Annex
NAD
Equipment connected to a telecommunication and
cable distribution networks and supplied with an
earphone intended to be held against, or in the ear
is required to comply with special acoustic pressure
requirements.
No TNV circuits.
N/A