Report No.: 50261218 001
National Differences
Clause
Requirement + Test
Result - Remark
Verdict
USA National Differences
- if it is part of a range that extends into the Table 2
"Normal Operating Conditions"
N/A
Likewise, a voltage rating is not to be lower than the
specified "Normal Operating Conditions," unless it is
part of a range that extends into the "Normal
Operating Conditions"
N/A
1.7.7
Wiring terminals intended to supply Class 2 outputs
in accordance with NEC or CEC Part 1 or NEC are
marked with the voltage rating and “Class 2” or
equivalent
N/A
- Marking is located adjacent to the terminals
N/A
- Marking is visible during wiring
N/A
2.5
Fuse providing Class 2, Limited Power Source, or
TNV current limiting is not operator
-accessible
unless it is not interchangeable
Not used for such kind of
equipment.
N/A
2.6
Equipment with isolated ground (earthing)
receptacles is in compliance with NEC 250.146(D)
and CEC 10
-112 and 10-906(8)
N/A
2.7.1
Suitable NEC/CEC branch circuit protection rated at
the maximum circuit rating is provided for all
standard supply outlets and receptacles (such as
supplied in power distribution units) if the supply
branch circuit protection is not suitable.
No such parts.
N/A
Power distribution transformers distributing power at
100 volts or more, and rated 10 kVA or more,
provided with special transformer overcurrent
protection
N/A
3.2
Wiring methods (terminals, leads, etc.) used for the
connection of the equipment to the mains is in
accordance with the NEC/CEC
N/A
3.2.1
Attachment plugs of power supply cords are rated
not less than 125 percent of the rated current of the
equipment
N/A
3.2.1.2
Equipment connected to a centralized d.c. power
system, and having one pole of the DC mains input
terminal connected to the main protective earthing
terminal in the equipment comply with special
earthing, wiring, marking and installation instruction
requirements
No connection to a
centralized d.c. power
system
.
N/A
3.2.3
Permanent connection of equipment to the mains
supply by a power supply cord is not permitted,
except for certain equipment, such as ATMs
N/A
3.2.5
Power supply cords are no longer than 4.5 m in
length
N/A