Safety Information

www.tuv.com
Page 6 of 59
Report No.: 50261218 001
TRF No. IEC60950_1G
Test item particulars ......................................... :
Equipment mobility.................................................:
[] movable [] hand-held [] transportable
[] stationary [] for building-in [x] direct plug-in
Connection to the mains........................................:
[x] pluggable equipment [x] type A [] type B
[] permanent
connection
[] detachable power supply cord
[] non
-detachable power supply cord
[] not directly connected to the mains
Operating condition................................................:
[x] continuous
[] rated operating / resting time:
Access location ......................................................:
[x] operator accessible
[] restricted access location
Over voltage category (OVC) ................................:
[] OVC I [x] OVC II [] OVC III [] OVC IV
[] other:
Mains supply tolerance (%) or absolute mains
supply values .........................................................:
±10% (requested by client)
Tested for IT power systems .................................:
[] Yes (only for Norway) [x] No
IT testing, phase-phase voltage (V) ......................:
N/A
Class of equipment ................................................:
[] Class I [x] Class II [] Class III
[] Not classified
Considered current rating of protective device as
part of the building installation (A)
.......................:
20A
Pollution degree (PD) .............................................:
[] PD 1 [x] PD 2 [] PD 3
IP protection class ..................................................:
IP20
Altitude during operation (m) ................................:
Up to 2000
Altitude of test laboratory (m) ...............................:
below 2000
Mass of equipment (kg) .........................................:
Approx. 0.223
Possible test case verdicts:
- test case does not apply to the test object......... :
N/A
- test object does meet the requirement .............. :
P (Pass)
- test object does not meet the requirement......... :
F (Fail)
Testing ............................................................ :
Date of receipt of test item ................................. :
See cover page
Date (s) of performance of tests ......................... :
See cover page
General remarks:
"(See Enclosure #)" refers to additional information appended to the report.
"(See
appended table)" refers to a table appended to the report.
Throughout this report a