Safety Information

Attachment 1
www.tuv.com Page 2 of 6 Report No.: 50261218 001
46.4 - Direct Plug-In Rod Pressure Test
Model: MZ90PD-1
Rod Pressure Point
Vol
tage
(Vpk)
Touch Current
Required?
Pin holder
type: PC
-
6610
, mfr.:
CHI MEI
CORPORATION
Center of enclosure face closest to
transformer
0.1 No
Note: --
Single-Phase Equipment - Figure 5a.
The test was made in all combinations to the normal and reverse polarity of the supply circuit (Polarity
Switch P1).
Terminal A (Switch "s")
of Measuring
Instrument Connected to:
Switch "e"
Position
Touch Current (mA r.m.s.)
Polarity P1/Primary Switch Condition
Normal/On
Normal/Off
Reverse/On
Reverse/Off
Enclosure with metal foil
--
--
--
--
--
The touch curren did not exceed 0.25 mA r.m.s with terminal A connected to the earth terminal of the unit
with Switch "e" closed.
Following the rod pressure test, the unit is to be subjected to the Dielectric Voltage Withstand Test(Clause
34),
Model:
MZ90PD-1
Point
Voltage
(Vpk)
Breakdown
Input blade to Enclosure
3000V
No