Safety Information

Attachment 1
www.tuv.com Page 3 of 6 Report No.: 50261218 001
7.11-Weight and moment determination: (Direct Plug-In Unit)
METHOD
The output cord was not included in the weight measurement.
Each sample was weighed and the distance to the center of gravity was measured using suitable
instruments. The distance between the center of the blades and the center of gravity was measured. The
moments were then calculated by taking the products of the above measurements.
W = Weight of the device.
S = The lesser of S
1
and S
2
.
S
1
= Distance from the center of the blades to the left side of the enclosure.
S
2
= Distance from the center of the blades to the right side of the enclosure.
X = The greater of X
1
and X
2
.
X
1
= Distance from the horizontal axis passing through the center of the blades to the center of gravity.
X
2
= Distance from the vertical axis passing through the center of the blades to the center of gravity.
Y = Distance from the face [ blade side ] to the center of gravity.
Z = The lesser of Z
1
and Z
2
.
Z
1
= Distance from the center of the blades to the top of the enclosure.
Z
2
= Distance from the center of the blades to the bottom of the enclosure.
WEIGHT AND MOMENT DETERMINATION: (DIRECT PLUG-IN UNIT) (CONT’D)
RESULTS
Values are in grams or millimeters.
Model
W
S
X
Y
Z
WY/Z
WY/S
WX
MZ90PD
-1
223g
15mm
14mm
33mm
23.5m
m
313.1g
490.6g
3122g.m
m
W did not exceed 794 grams, WY/Z did not exceed 1361 grams, WY/S did not exceed 1361 grams, and
WX did not exceed 0.56 Nm (57606 gram-millimeters).
* The unit of WX is gram-millimeter.