Safety Information

www.tuv.com
Page 7 of 59
Report No.: 50261218 001
TRF No. IEC60950_1G
Manufacturer’s Declaration per sub-clause 4.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory has
been provided
................................
.................... :
Yes
Not applicable
When differences exist; they shall be identified in the
section.
Name and address of factory (ies)...................... :
Shenzhen Mazepower Technology Ltd.
Room
707, 7/F, Tower A, Da Tang Shi Dai Building,
No.
2203 Meilong Avenue, Long Hua District,
ShenZhen, China
General product information:
1. The equipment is a switching power adapter (Direct plug-in type) for the use with information
technology equipment. Only US plug is applied in this report.
2. The equipment having a 90
o
rotatable US plug has been tested according to UL
1310 (attachment 1).
3. Top enclosure
and bottom enclosure are sealed together by snap in fixation plus ultrasonic welding
the plug is fixed firmly, and this method effectively prevents any disintegration or conductiv
e parts
remaining in the socket.
4. All Models are identical except for model number and output rating, see table below for details.
Table A: Model difference table
Models
Output
MZ90PD-1
5Vd.c. 3A or 9Vd.c. 3A or 12Vd.c. 3A or 15Vd.c. 3A or 20Vd.c. 4.5A
MZ90PD-2
5Vd.c. 2.4A or 9Vd.c. 3A or 12Vd.c. 3A or 15Vd.c. 3A or 20Vd.c. 4.5A
MZ87PD-1
5Vd.c. 3A or 9Vd.c. 3A or 12Vd.c. 3A or 15Vd.c. 3A or 20Vd.c. 4.35A
MZ87PD-2
5Vd.c. 2.4A or 9Vd.c. 3A or 12Vd.c. 3A or 15Vd.c. 3A or 20Vd.c. 4.35A
MZ65PD-1
5Vd.c. 3A or 9Vd.c. 3A or 12Vd.c. 3A or 15Vd.c. 3A or 20Vd.c. 3.25A
MZ65PD-2
5Vd.c. 2.4A or 9Vd.c. 3A or 12Vd.c. 3A or 15Vd.c. 3A or 20Vd.c. 3.25A
MZ61PD-1
5Vd.c. 3A or 9Vd.c. 3A or 12Vd.c. 3A or 15Vd.c. 3A or 20Vd.c. 3.05A
MZ61PD-2
5Vd.c. 2.4A or 9Vd.c. 3A or 12Vd.c. 3A or 15Vd.c. 3A or 20Vd.c. 3.05A
MZ45PD-1
5Vd.c. 3A or 9Vd.c. 3A or 12Vd.c. 3A or 15Vd.c. 3A or 20Vd.c. 2.25A
MZ45PD-2
5Vd.c. 2.4A or 9Vd.c. 3A or 12Vd.c. 3A or 15Vd.c. 3A or 20Vd.c. 2.25A
Abbreviations used in the report:
- normal conditions
N.C. - single fault conditions S.F.C
- functional insulation
FI - basic insulation BI
- double insulation
DI - supplementary insulation SI
- between parts of opposite
polarity
BOP - reinforced insulation RI