Safety Information

www.tuv.com
Page 8 of 59
Report No.: 50261218 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1G
1
GENERAL
P
1.5
Components
P
1.5.1
General
P
Comply with IEC 60950-1 or relevant component
standard
(see appended tables 1.5.1)
P
1.5.2
Evaluation and testing of components
Components which are
certified to IEC and/or national
standards are used correctly
within their ratings.
Components not covered by
IEC standards are tested
under the conditions present in
the equipment.
P
1.5.3
Thermal controls
No thermal controls.
N/A
1.5.4
Transformers
Transformers used are
suitable for t
heir intended
application and comply with
the relevant requirements of
the standard and particularly
Annex C.
P
1.5.5
Interconnecting cables
P
1.5.6
Capacitors bridging insulation
Between primary and
secondary:
Y1 capacitor (CY1)
according to IEC 60384
-14
used.
Between Line and Neutral: X2
capacitor (
CX1)
according to
IEC 60384-14 used.
P
1.5.7
Resistors bridging insulation
N/A
1.5.7.1
Resistors bridging functional, basic or
supplementary insulation
No such resistors.
N/A
1.5.7.2
Resistors bridging double or reinforced insulation
between a.c. mains and other circuits
N/A
1.5.7.3
Resistors bridging double or reinforced insulation
between a.c. mains and antenna or coaxial cable
N/A
1.5.8
Components in equipment for IT power systems
N/A
1.5.9
Surge suppressors
Approved surge suppressor
MOV1 used.
P
1.5.9.1
General
Comply to Annex Q
P
1.5.9.2
Protection of VDRs
Protected by a current fuse
before the VDR.
P
1.5.9.3
Bridging of functional insulation by a VDR
MOV1 bridged between L and
N after fuse.
P