Safety Information

www.tuv.com
Page 9 of 59
Report No.: 50261218 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1G
1.5.9.4
Bridging of basic insulation by a VDR
No such construction.
N/A
1.5.9.5
Bridging of supplementary, double or reinforced
insulation by a VDR
N/A
1.6
Power interface
P
1.6.1
AC power distribution systems
TN power system
P
1.6.2
Input current
Highest load according to
1.2.2.1 for this equipment is the
operation with the maximum
specified by the manual
instruction.
(see appended
table 1.6.2)
P
1.6.3
Voltage limit of hand-held equipment
This appliance is not hand-
held equipment.
N/A
1.6.4
Neutral conductor
The neutral conductor
insulated from earth and from
the body throughout the
equipment as if it were a line
conductor.
P
1.7
Marking and instructions
P
1.7.1
Power rating and identification markings
See below
P
1.7.1.1
Power rating marking
P
Multiple mains supply connections..........................:
Single power source
P
Rated voltage(s) or voltage range(s) (V) ............. :
100-240V~
P
Symbol for nature of supply, for d.c. only ............ :
AC source
P
Rated frequency or rated frequency range (Hz) ... :
50/60Hz
P
Rated current (mA or A) .................................. :
2A
P
1.7.1.2
Identification markings
P
Manufacturer’s name or trade-mark or identification
mark ............................................................. :
See copy of marking plate.
P
Model identification or type reference ................ :
See copy of marking plate.
P
Symbol for Class II equipment only ................... :
60417-1-IEC-5172 symbol
marked.
P
Other markings and symbols ........................... :
Additional symbol or marking
does not give rise to
misunderstanding.
P
1.7.1.3
Use of graphical symbols
N/A
1.7.2
Safety instructions and marking
Eng
lish instruction
version
provided.
P