User's Manual

Table Of Contents
1. Power ON/OFF
2. Power inlet IEC
Connect to the wall outlet .
Tips:
You can insert your existing AC iPurifiers into the PowerStation
to enhance your system.
The more AC iPurifiers used, the cleaner the overall power.
On the PowerStation, if an AC iPurifier is placed in the middle,
this AC iPurifier will also act as a extra noise shield. Any noise is
reduced, isolated and confined to the respective left/right
sections of the AC iPurifier.
3. Polarity/Earth detection
The following table depicts the different readings and the
respective LED colour combinations. Where needed, make the
necessary system adjustments.
4 Ground/Earth. connection
The 4mm banana socket fitted to the PowerStation can be used
to create a supplementary ground/earth connection for audio
systems where there is no ground/earth present.
The supplementary ground/earth connection is ‘smart as it will
NOT introduce a ground loop EVEN if the system is already
earthed (as more than one earth also creates a ground loop).
5. Over-voltage Surge Protection
In the rare instance of excessive Over-voltage OR a short in the
mains electricity, the Over-voltage Surge Protection (OSP) is an
auto detection and cut-off circuit.
It will take several minutes for the PowerStation to reboot BUT if
the Over-voltage or short persists, then the PowerStation will
NOT power on, thereby protecting the downstream audio
system from harm. If this occurs, please have a qualified
electrician inspect your mains.
Disclaimer: Although the PowerStation does its utmost to protect
the audio system from electric harm, AMR/iFi does not guarantee
this.
Features
• Active Noise Cancellation2 technology
TM
• Solid PurCopper Bus-Bars for power transfer
• Individual noise isolation chambers - for each outlet
TM
• High-performance PurCopper outlets
• Heavy OFHC Continuous Cast Copper internal wiring
• Polarity and earth diagnostic system
• Advanced surge & transient protection system
• Dedicated chassis grounding system
• 2500W-10A MAX 250
Specifications
Noise reduction:
Surge Protection:
Operating Voltage:
Dimensions:
Weight:
Warranty period:
Specifications are subject to change without notice.
CAUTION: RISK OF ELECTRIC SHOCK DO NOT PLUG INTO ANOTHER RELOCATABLE
POWER TAP. TO REDUCE THE RISK OF ELECTRIC SHOCK, USE ONLY INDOORS AND
IN DRY LOCATIONS.
DO NOT INSTALL THIS DEVICE IF THERE IS NOT AT LEAST 10 METERS OR WIRE
BETWEEN THE ELECTRICAL OUTLET AND THE ELECTRICAL SERVICE PANEL.
NO FOR USE WITH AQUARIUMS AND ALL OTHER WATER-RELATED PRODUCTS.
Ver1.1
ifi-audio.com
PowerStation
Earth
Polarity
31 2
4
Polarity Earth Status
2
Polarity error. Live and Neutral
connections are reversed.
Ground error. Earth is missing
or faulty (e.g. resistance too high).
3
Red
Cut-out mode. Over-voltage
or an electrical short.
4
Off Off
Red
Red
1
(LED) (LED)
Normal
GreenGreen
Green
> 40dB (> 100x)
max. 30,000A @ 1,000V/10uS
90V - 265V
478(l) x96 (w) x76 (h) mm
1.98kg (4.37 Ibs)
12 months